Fatigue behavior of Ilizarov frame versus tibial interlocking nail in a comminuted tibial fracture model: a biomechanical study
نویسندگان
چکیده
BACKGROUND Treatment options for comminuted tibial shaft fractures include plating, intramedullary nailing, and external fixation. No biomechanical comparison between an interlocking tibia nail with external fixation by an Ilizarov frame has been reported to date. In the present study, we compared the fatigue behaviour of Ilizarov frames to interlocking intramedullary nails in a comminuted tibial fracture model under a combined loading of axial compression, bending and torsion. Our goal was to determine the biomechanical characteristics, stability and durability for each device over a clinically relevant three month testing period. The study hypothesis was that differences in the mechanical properties may account for differing clinical results and provide information applicable to clinical decision making for comminuted tibia shaft fractures. METHODS In this biomechanical study, 12 composite tibial bone models with a comminuted fracture and a 25 mm diaphyseal gap were investigated. Of these, six models were stabilized with a 180-mm four-ring Ilizarov frame, and six models were minimally reamed and stabilized with a 10 mm statically locked Russell-Taylor Delta tibial nail. After measuring the pre-fatigue axial compression bending and torsion stiffness, each model was loaded under a sinusoidal cyclic combined loading of axial compression (2.8/28 lbf; 12.46/124.6 N) and torque (1.7/17 lbf-in; 0.19/1.92 Nm) at a frequency of 3 Hz. The test was performed until failure (implant breakage or >or= 5 degrees angulations and/or 2 cm shortening) occurred or until 252,000 cycles were completed, which corresponds to approximately three months testing period. RESULTS In all 12 models, both the Ilizarov frame and the interlocking tibia nail were able to maintain fracture stability of the tibial defect and to complete the full 252,000 cycles during the entire study period of three months. A significantly higher stiffness to axial compression and torsion was demonstrated by the tibial interlocking nail model, while the Ilizarov frame provided a significantly increased range of axial micromotion. CONCLUSION This is the first study, to our knowledge, which compares the biomechanical properties of an intramedullary nail to an external Ilizarov frame to cyclic axial loading and torsion in a comminuted tibia shaft fracture model. Prospective, randomized trials comparing Ilizarov frames and interlocked tibial nails are needed to clarify the clinical impact of these biomechanical findings.
منابع مشابه
Management of tibial non-:union: using reamed interlocking intra-medullary nailing
Abstract Background: Reamed interlocking intramedullary nailing of the tibia is a procedure for the treatment of a non-infected tibial non:::union:::. The purpose of this clinical study was to evaluate the outcome of this method as a treatment of tibial non:::union:::. Methods: Twenty-nine patients with non:::union::: after initial therapy for tibial fracture were retrospectively assessed...
متن کاملA biomechanical comparison of the Surgical Implant Generation Network (SIGN) tibial nail with the standard hollow nail.
OBJECTIVE In developing countries, tibial shaft fractures are frequently stabilised using Surgical Implant Generation Network (SIGN) nails. Despite widespread use throughout the world, little is known regarding their biomechanical properties. This study aimed to compare the mechanical stiffness of the SIGN tibial nail with a standard hollow tibial nail. METHODS A fracture gap model was create...
متن کاملRetrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
BACKGROUND Currently, antegrade intramedullary nailing and minimally invasive plate osteosynthesis (MIPO) represent the main surgical alternatives in distal tibial fractures. However, neither choice is optimal for all bony and soft tissue injuries. The Retrograde Tibial Nail (RTN) is a small-caliber prototype implant, which is introduced through a 2-cm-long incision at the tip of the medial mal...
متن کاملTreatment of comminuted tibial shaft fractures in four dogs with the use of interlocking nail connected with type I external fixator.
The treatment of comminuted tibial shaft fractures in canine patients is burdened by significant risk which involves bone healing complications, such as delayed bone union. Complications may result from iatrogenic damage to blood vessels during fracture stabilization. To minimize this risk, treatment methods increasingly often rely on the concept of biological osteosynthesis. One of such method...
متن کاملAdult tibial shaft fractures – different patterns, various treatments and complications
BACKGROUND Tibial Fractures constitute a large number of emergency operations in most trauma centers. There are different approaches for tibial fractures. To our knowledge, there is insufficient evidence to consider post-operative complications in relation to both surgical methods and the types of fractures. Our purpose is to report our experience regarding the efficacy and complications associ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Orthopaedic Surgery and Research
دوره 1 شماره
صفحات -
تاریخ انتشار 2006