Condylar buttress plate versus fixed angle condylar blade plate versus dynamic condylar screw for supracondylar intra-articular distal femoral fractures.
نویسندگان
چکیده
PURPOSE To compare outcomes of 3 fixation techniques for intra-articular distal femoral fractures. METHODS Records of 59 men and 49 women aged 16 to 80 (mean, 47) years who underwent internal fixation for 116 type-C (complete intra-articular) distal femoral fractures were retrospectively reviewed. According to the AO classification, 25 fractures were type C1 (23 closed and 2 open), 71 type C2 (69 closed and 2 open), and 20 type C3 (16 closed and 4 open). Based on implant availability at the time, all surgeries were performed by a single surgeon using a condylar buttress plate (n=38), a fixed angle (95 degrees) condylar blade plate (n=24), or a dynamic condylar screw (n=54). The mean follow-up period was 11 (range, 4-19) years. At the latest follow-up, functional outcome was classified according to Schatzker and Lambert criteria. RESULTS Functional outcomes were excellent in 64 (55%) of the fractures, good in 37 (32%), moderate in 9 (8%), and poor in 6 (5%). Outcomes in patients treated by the dynamic condylar screw were significantly superior to those treated by the condylar buttress plate (p=0.016) or condylar blade plate (p=0.001). Good-to-excellent results were achieved in 96% vs 84% vs 71% of these patients, respectively. Complication rates were lower in the dynamic condylar screw group than the other 2 groups (pseudarthrosis, 5% vs 11% vs 25%; varus deformity, 4% vs 26% vs 25%; knee stiffness, 0% vs 5% vs 8%, respectively). No implant failure was encountered. CONCLUSION Dynamic condylar screw fixation for distal femoral fractures achieves better functional outcomes and lower complication rates.
منابع مشابه
Condylar Buttress Plate for Fixation of Distal Femur Fracture: Functional and Anatomical Evaluation
Background: Distal Femur fractures are one of the common fractures occurring in road traffic accidents. Various modalities are used for fracture of distal femur, one of them is condylar buttress plate. Various studies have claimed better results in surgical management of distal femur fracture. This study was planned to compare two treatment modalities for supracondylar and intercondylar fractur...
متن کاملFailure of Distal Femoral Locking Plate: Case Report
The Less Invasive Stabilization System (LISS) and titanium distal femoral locking compression plate (DF-LCP) was designed by the AO Group to combine the advantages of both interlocked intra-medullary nailing and biological plating techniques in one system. The stiffness of the construct is similar to a 95° condylar plate, dynamic condylar screw, or condylar buttress plate. We report a case of t...
متن کاملIs Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?
In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...
متن کاملOriginal Contribution TREATMENT OF FRACTURES OF THE DISTAL FEMORAL – OVERVIEWS OF OSTEOSYNTHESIS FUNDS
Distal femoral fractures thigh up from 4 to 9% of all fractures of the femur. There is a direct relationship between the mechanism of receipt of the lesion and the age, sex and the type of fracture. Caused mainly by high-traumatic effects and lead to a high degree of disability. For these reasons, injuries in this anatomical area are of great social importance. The goal of the distal femur frac...
متن کاملFixation of Supracondylar Femoral Fractures: a Biomechanical Analysis Comparing 95° Blade Plates and Dynamic Condylar Screws (dcs)
OBJECTIVE To determine, by means of comparative biomechanical tests, whether greater compressive load resistance and flexion is presented by 95° angled blade plates or by dynamic condylar screws (DCS), and to correlate the failure type presented during the tests with each type of plate. METHODS Sixty-five porcine femurs were subjected to 1 cm medial wedge osteotomy, in the metaphysis, to simu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic surgery
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2010