Slit slat collimator optimization with respect to MTF.

نویسندگان

  • A Kamali-Asl
  • S Sarkar
  • M Shahriari
  • H Agha-Hosseini
چکیده

Conventional single photon emission computed tomography (SPECT) collimators are not suitable for 511 keV imaging. In order to use a SPECT system for single positron emission tomography (SPET), we need to design high-efficiency collimators capable of absorbing 511 keV photons. Slit slat (SS) collimators have been proposed for this purpose even though the optimization of such collimators has not yet been performed. In order to investigate the reliability of the system with SS collimator, it was decided to evaluate such a system. A gamma camera system with both parallel hole (PH) and SS collimators was simulated by Monte Carlo method. In these simulation parameters of the simulated system having 3/8 in NaI(Tl) crystal for 140 keV gamma-rays with PH collimator was compared with practical results and a good correlation was found between the simulated and practical results. In this way, the validity of our simulation code was confirmed. The crystal thickness for simulated gamma-camera system with SS collimator for detection of 511 keV photons was set to be 5/8 in which resulted in an intrinsic spatial resolution of 4mm. The simulated SS collimators consisted of 50 lead plates of various height, thickness and spacing. The imaging was performed by rotating the SS collimator from 0 degrees to 180 degrees in 73 steps of 2.5 degrees each. The physical parameters such as spatial resolution, efficiency and modulation transfer function (MTF) of this system for different SS collimator designs, (i.e. SS(64,3,3), SS(80,3,3), SS(64,4,5), SS(80,4,5), SS(85,4,5), where in SS(h,s,t) is used to indicate the septal height (h), septal separation (s), and septal thickness (t) in millimeters were evaluated. The value of these parameters were compared with the values obtained employing a 511 keV PH(85,4,2.5) collimator. Based on MTF values, our result showed that the SS(85,4,5) collimator has an optimum performance to the other SS collimators. The relative efficiency of the system with SS(85,4,5) collimator was about 20 times higher than the efficiency of the system with the PH(85,4,2.5) collimator whereas in this case the spatial resolution had deteriorated by almost 8% (i.e. from 14.1 to 15.0 mm). The result of this study shows that the SS collimators have great advantages over the conventional PH collimators for 511 keV imaging, providing much higher efficiency while maintaining a comparable spatial resolution. Employing this collimator makes it possible to use a SPECT system for metabolic imaging by SPET system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

متن کامل

Collimator design for a clinical brain SPECT/MRI insert

The Institute of Nuclear Medicine, University College London, London, UK This project’s goal is to design a SPECT insert for a clinical MRI system for simultaneous brain SPECT/MR imaging. We assume the stationary SPECT insert will consist of two rings of ∼5x5-cm SiPM-based detectors insensitive to magnetic fields, with 0.8-mm intrinsic resolution. The maximum diameter is 44.5 cm, the minimum di...

متن کامل

Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

متن کامل

Intercomparison of methods for image quality characterization. I. Modulation transfer function.

The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of the results. As a part of a study aimed at comparing the relative performance o...

متن کامل

Image reconstruction algorithm for a rotating slat collimator.

A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted plan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 62 3  شماره 

صفحات  -

تاریخ انتشار 2005