Reopening after successful coil occlusion for patent ductus arteriosus.

نویسندگان

  • C J Daniels
  • S C Cassidy
  • D W Teske
  • J J Wheller
  • H D Allen
چکیده

OBJECTIVES This study was performed to determine the frequency of patent ductus arteriosus (PDA) reopening and the factors that may predict reopening after successful coil occlusion. BACKGROUND Transcatheter coil occlusion is a widely used and accepted method to close a PDA. After documented successful coil occlusion, we found PDAs that reopened. We hypothesized that specific factors are involved in those that reopened. METHODS All patients who underwent percutaneous transarterial PDA coil occlusion were studied. Successful coil occlusion was documented. PDA reopening was determined when Doppler-echocardiography (DE) performed after the procedure was negative for PDA flow but at follow-up demonstrated PDA shunting. Patients with a reopened PDA were compared with all other patients in evaluating independent variables. RESULTS Coil occlusion for PDA was attempted in 22 patients. Clinical success was achieved in 20 patients (91%), and DE was negative for PDA shunting in 19 patients (90%). At follow-up, five patients demonstrated reopening. The PDA minimal diameter was 1.4 +/- 0.5 mm (mean +/- SD) for the reopened group and 1.2 +/- 0.7 mm for the other patients. The PDA length was 2.9 +/- 1.9 mm for the reopened group and 7.1 +/- 3.2 mm for all other patients. All those with type B PDA were in the reopened group. When independent variables were compared between groups, only PDA length and type B PDA predicted reopening (p < 0.05). CONCLUSIONS PDA reopening may occur after successful coil occlusion. Short PDA length and type B PDA are associated with reopening. The data suggest that in such anatomy, alternative strategies to the current coil occlusion technique should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful transcatheter balloon dilatation of coarctation of aorta and coil occlusion of patent ductus arteriosus in a single catheterization procedure.

Simultaneous transcatheter coil occlusion of patent ductus arteriosus and balloon angioplasty of coarctation of aorta is avoided since intimal tearing after angioplasty is believed to increase the risk for dissection of the aorta during catheter manipulation. We report a 14-month-old boy, with weight of 7.6 kg, with aortic coarctation and patent ductus arteriosus with a large left-to-right shun...

متن کامل

Transcatheter occlusion of patent ductus arteriosus with Gianturco coils.

BACKGROUND Transcatheter occlusion with Gianturco coils has been attempted in a small number of patients with tiny (< or = 1.5-mm diameter) patent ductus arteriosus, and preliminary results have been encouraging. The present study extends this method to larger ductus sizes and makes recommendations for proper coil size selection. METHODS AND RESULTS Coil occlusion was attempted in 24 consecut...

متن کامل

Delayed Fracture of a PFM Nit-Occlud Flex Coil after Transcatheter Occlusion of Patent Ductus Arteriosus

We report the fracture of a 4×4 Nit-Occlud pfm coil in a child with patent ductus arteriosus (PDA), bicuspid aortic valve, and coarctation, detected three years after deployment without any adverse consequent. This report emphasizes the importance of adherence to the user guidelines of the company for the implementation of the device and also shows the significance of lateral chest X-ray in the...

متن کامل

Does change in serum cholesterol of a population influence coronary heart disease mortality?

[1] Shim D, Fedderly RT, Beekman III RH, Ludomirsky A, Young ML, Schork MA, Lloyd TR. Follow-up of coil occlusion of patent ductus arteriosus. J Am Coll Cardiol 1996; 28. 207-11. [2] Galal O, de Moor M, Fadley F et al. Problems encountered during introduction of Gianturco coils for transcatheter occlusion of the patent arterial duct. Eur Heart J 1997; 18: 625-30. [3] Sommer RJ, Gutierrez A, Lai...

متن کامل

Long-term outcome of coil occlusion in patients with patent ductus arteriosus.

BACKGROUND Coil occlusion has been widely indicated for the closure of patent ductus arteriosus (PDA). Although many reports have shown the efficacy and safety of coil occlusion, the long-term outcome in patients remains controversial. Here, we analyzed the long-term outcome of coil occlusion in patients with PDA in Japan. METHODS AND RESULTS We collected the longitudinal data of patients who...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 1998