High-throughput identification of bacteria and yeast by matrix-assisted laser desorption ionization-time of flight mass spectrometry in conventional medical microbiology laboratories.
نویسندگان
چکیده
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is suitable for high-throughput and rapid diagnostics at low costs and can be considered an alternative for conventional biochemical and molecular identification systems in a conventional microbiological laboratory. First, we evaluated MALDI-TOF MS using 327 clinical isolates previously cultured from patient materials and identified by conventional techniques (Vitek-II, API, and biochemical tests). Discrepancies were analyzed by molecular analysis of the 16S genes. Of 327 isolates, 95.1% were identified correctly to genus level, and 85.6% were identified to species level by MALDI-TOF MS. Second, we performed a prospective validation study, including 980 clinical isolates of bacteria and yeasts. Overall performance of MALDI-TOF MS was significantly better than conventional biochemical systems for correct species identification (92.2% and 83.1%, respectively) and produced fewer incorrect genus identifications (0.1% and 1.6%, respectively). Correct species identification by MALDI-TOF MS was observed in 97.7% of Enterobacteriaceae, 92% of nonfermentative Gram-negative bacteria, 94.3% of staphylococci, 84.8% of streptococci, 84% of a miscellaneous group (mainly Haemophilus, Actinobacillus, Cardiobacterium, Eikenella, and Kingella [HACEK]), and 85.2% of yeasts. MALDI-TOF MS had significantly better performance than conventional methods for species identification of staphylococci and genus identification of bacteria belonging to HACEK group. Misidentifications by MALDI-TOF MS were clearly associated with an absence of sufficient spectra from suitable reference strains in the MALDI-TOF MS database. We conclude that MALDI-TOF MS can be implemented easily for routine identification of bacteria (except for pneumococci and viridans streptococci) and yeasts in a medical microbiological laboratory.
منابع مشابه
Desorption Ionization-Time of Flight Mass Spectrometry
Advances in the Identification of Clinical Yeast Isolates Using Matrix-Assisted Laser 1 Desorption Ionization-Time of Flight Mass Spectrometry 2 3 Blake W. Buchan and Nathan A. Ledeboer 4 Department of Pathology, Medical College of Wisconsin, and Dynacare Laboratories, 9200 W. 5 Wisconsin Ave., Milwaukee, WI 53226. 6 7 Running Title: Identification of Yeast Using MALDI-TOF 8 9 Correspondence: N...
متن کاملPerformance of the Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories.
We evaluated the performance of the Vitek MS for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories. With a total of 424 well-characterized isolates, the results of the Vitek MS were compared to those of conventional methods and 16S rRNA gene sequencing. The Vitek MS correctly identified 97.9 % of the isolates tested to species level. The Vitek MS cor...
متن کاملTOF) mass spectrometry methods and API 20AN for identification of clinically relevant
2 5 Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) 2 6 is suitable for high-throughput and rapid microbial diagnosis at relatively low costs and can be 2 7 considered an alternative for conventional biochemical and molecular identification systems in a 2 8 Clinical Microbiological Laboratory including anaerobe laboratory. Two commercially available
متن کاملAdvances in the Identification of Clinical Yeast Isolates Using Matrix-Assisted Laser
Advances in the Identification of Clinical Yeast Isolates Using Matrix-Assisted Laser 1 Desorption Ionization-Time of Flight Mass Spectrometry 2 3 Blake W. Buchan and Nathan A. Ledeboer 4 Department of Pathology, Medical College of Wisconsin, and Dynacare Laboratories, 9200 W. 5 Wisconsin Ave., Milwaukee, WI 53226. 6 7 Running Title: Identification of Yeast Using MALDI-TOF 8 9 Correspondence: N...
متن کاملApplication of MALDI-TOF MS for the Identification of Food Borne Bacteria
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful tool for the routine identification of clinical isolates. MALDI-TOF MS based identification of bacteria has been shown to be more rapid, accurate and cost-efficient than conventional phenotypic techniques or molecular methods. Rapid and reliable identification of food-a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 48 3 شماره
صفحات -
تاریخ انتشار 2010