CFD modeling of incinerator to increase PCBs removal from outlet gas
نویسندگان
چکیده
Incineration of persistent organic pollutants (POPs) is an important alternative way for disposal of this type of hazardous waste. PCBs are very stable compounds and do not decompose readily. Individuals can be exposed to PCBs through several ways and damaged by their effects. A well design of a waste incinerator will convert these components to unharmfull materials. In this paper we have studied the design parameters of an incinerator with numerical approaches. The CFD software Fluent 6.3 is used for modelling of an incinerator. The effects of several baffles inside the incinerator on flow distribution and heat is investigated. The results show that baffles can reduce eddy flows, increase retaining times, and efficiencies. The baffles reduced cool areas and increased efficiencies of heat as maximum temperature in two and three baffle embedded incinerator were 100 and 200 °C higher than the non-baffle case, respectively. Also the gas emission leaves the incinerator with a lower speed across a longer path and the turbulent flow in the incinerator is stronger.
منابع مشابه
investigation of mercaptan removal from Kerosene using passive mixing tools: Experimental study and CFD modeling
Abstract In this work, the role of appropriate mixing for mercaptan removal from Kerosene using caustic soda has been investigated in the pilot scale. Static mixer at different condition has been used as a passive mixing tool to achieve proper mixing and consequently high performance of mercaptan removal. Two lengths of static mixer including 20 and 40 cm as well as two pitches 1 and 3 m...
متن کاملModeling and Experimental Study of Carbon Dioxide Absorption in a Flat Sheet Membrane Contactor
comIn the present study, CO2 removal from natural gas stream has been studied using a flat sheet membrane contactor. A three dimensional mathematical model is developed to describe the process. The model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. The model is based on the non-wetted mode of operation, in which t...
متن کاملStudy on the Particle Removal Efficiency of Multi Inner Stage Cyclone by CFD Simulation
A new multi inner stage (MIS) cyclone was designed to remove the acidic gas and fine particles produced from electronic industry. To characterize gas flow in MIS cyclone, pressure and velocity distribution were calculated by means of CFD program. Also, the flow locus of fine particles and particle removal efficiency were analyzed by Lagrangian method. When outlet pressure condition was –100mmAq...
متن کاملModeling and Simulation of CO2 Absorption Enhancement in Hollow-Fiber Membrane Contactors using CNT–Water-Based Nanofluids
Absorption of CO2 from a gas mixture containing CO2 and nitrogen by water-based CNT nanofluids in gas–liquid hollow fiber membrane contactor was modeled and solved using COMSOL Multiphysics 5.4. The model assumed partial wetting of the membrane, along with diffusion in the axial and radial directions. In addition, Brownian motion and grazing effects were both considered in the model. The main c...
متن کاملCFD Study on Hydrogen-Air Premixed Combustion in a Micro Scale Chamber
This paper reports a CFD modeling study to investigate the hydrogen-air mixture combustion in a micro scale chamber. Nine species with nineteen reversible reactions were considered in the premixed combustion model. The effect of operational and geometrical conditions including; combustor size, wall conductivity, reactant flow rates and hydrogen feed splitting on combustion stabilit...
متن کامل