Temperature-Sensitive Indicators for Monitoring RBC Concentrates Out of Controlled Temperature Storage.
نویسندگان
چکیده
OBJECTIVES The 30-minute rule for RBC concentrates out of controlled temperature storage does not take into account multiple parameters that influence warming of RBC concentrates. This study evaluated two temperature-sensitive indicators (TIs) for monitoring RBC concentrates during transport. METHODS TI labels (Check-Spot [Harald H. Temmel KG, Gleisdorf, Austria] and Thermoindikator V4 [BASF, Basel, Switzerland]) were attached to RBC concentrates prior to delivery. Duration of transport, ambient temperatures, and label results (valid vs expired) were recorded. We evaluated the proportion of labels discrepant to the 30-minute rule overall and among deliveries 30 minutes or less and more than 30 minutes and compared the rates of valid and expired readings between both TIs. RESULTS In total, 201 RBC concentrate deliveries (86.6%) lasted 30 minutes or less, and 31 (13.4%) were more than 30 minutes. Forty-six (19.8%) Check-Spot and 37 (15.9%) Thermoindikator V4 results were discrepant to the 30-minute rule. Sixteen (51.6%) and 27 (87.1%) RBC concentrate deliveries more than 30 minutes displayed valid label readings with Check-Spot and Thermoindikator V4, respectively. Rates of expired labels among deliveries 30 minutes or less and valid labels among deliveries more than 30 minutes differed significantly between TIs (P < .01). CONCLUSIONS TIs identified a considerable number of RBC concentrates whose temperatures may not be adequately reflected by the 30-minute rule. Variability of readings between TIs stresses the necessity of validation prior to implementation.
منابع مشابه
Influence of temperature, filter wettability, and timing of filtration on the removal of WBCs from RBC concentrates.
BACKGROUND The efficacy of the removal of WBCs from buffy coat-reduced RBC concentrates by filtration is determined by many variables. The aim of this study was to investigate the influence of the filtration temperature, the wettability of the filter material, and the timing of the filtration after collection. STUDY DESIGN AND METHODS The investigation used commercially available filters: 3 d...
متن کاملTemperature-sensitive labels for containers of RBCs.
Temperature-sensitive labels are adhesive tags that display color changes at preset temperatures. There have been no studies of the suitability of this technology for measuring the temperature of blood components during transportation and storage. We used a digital thermometer to measure temperature in different locations inside containers of RBC as they were allowed to warm to ambient temperat...
متن کاملThermometry of Red Blood Cell Concentrate: Magnetic Resonance Decoding Warm Up Process
PURPOSE Temperature is a key measure in human red blood cell concentrate (RBC) quality control. A precise description of transient temperature distributions in RBC units removed from steady storage exposed to ambient temperature is at present unknown. Magnetic resonance thermometry was employed to visualize and analyse RBC warm up processes, to describe time courses of RBC mean, surface and cor...
متن کاملMonitoring the Freshness of Rainbow Trout Using Intelligent PH-sensitive Indicator During Storage
Background: The rainbow trout fish is susceptible to spoilage due to its high content of unsaturated fatty acids. It should be kept at low temperature to reduce microbial, enzymatic, and oxidation reactions. The purpose of this study was to design a packaging that contains a pH indicator for monitoring freshness of the rainbow trout fish during storage at refrigerator. Methods: The indicator co...
متن کاملUse of 2-furoylmethyl derivatives of GABA and arginine as indicators of the initial steps of maillard reaction in orange juice.
The formation of 2-furoylmethyl derivatives of GABA (2-FM-GABA) and arginine (2-FM-Arg) as early indicators of nonenzymatic browning in different types of orange juice was studied. In dehydrated orange juice, the presence of 2-FM-GABA and 2-FM-Arg was detected from the first day of storage at 30 degrees C. In this type of juice, the content of these two compounds increased with temperature (30,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of clinical pathology
دوره 144 1 شماره
صفحات -
تاریخ انتشار 2015