Fitting psychometric functions using a fixed-slope parameter: an advanced alternative for estimating odor thresholds with data generated by ASTM E679.
نویسندگان
چکیده
Psychometric functions are predominately used for estimating detection thresholds in vision and audition. However, the requirement of large data quantities for fitting psychometric functions (>30 replications) reduces their suitability in olfactory studies because olfactory response data are often limited (<4 replications) due to the susceptibility of human olfactory receptors to fatigue and adaptation. This article introduces a new method for fitting individual-judge psychometric functions to olfactory data obtained using the current standard protocol-American Society for Testing and Materials (ASTM) E679. The slope parameter of the individual-judge psychometric function is fixed to be the same as that of the group function; the same-shaped symmetrical sigmoid function is fitted only using the intercept. This study evaluated the proposed method by comparing it with 2 available methods. Comparison to conventional psychometric functions (fitted slope and intercept) indicated that the assumption of a fixed slope did not compromise precision of the threshold estimates. No systematic difference was obtained between the proposed method and the ASTM method in terms of group threshold estimates or threshold distributions, but there were changes in the rank, by threshold, of judges in the group. Overall, the fixed-slope psychometric function is recommended for obtaining relatively reliable individual threshold estimates when the quantity of data is limited.
منابع مشابه
The slope of the psychometric function and non-stationarity of thresholds in spatiotemporal contrast vision
The slope of the two-interval, forced-choice psychometric function (e.g. the Weibull parameter, β) provides valuable information about the relationship between contrast sensitivity and signal strength. However, little is known about how or whether β varies with stimulus parameters such as spatiotemporal frequency and stimulus size and shape. A second unresolved issue concerns the best way to es...
متن کاملA maximum-likelihood procedure for estimating psychometric functions: thresholds, slopes, and lapses of attention.
Green [J. Acoust. Soc. Am. 87, 2662-2674 (1990)] suggested an efficient, maximum-likelihood-based approach for adaptively estimating thresholds. Such procedures determine the signal strength on each trial by first identifying the most likely psychometric functions among the pre-proposed alternatives based on responses from previous trials, and then finding the signal strength at the "sweet poin...
متن کاملPsychometric functions for frequency discrimination from listeners with sensorineural hearing loss.
Psychometric functions for pulsed pure-tone frequency discrimination were obtained from hearing-impaired listeners at frequencies with normal hearing and at frequencies with mild or moderate hearing losses. The general form of psychometric functions at hearing-impaired frequencies was found to be the same as at normal-hearing frequencies, i.e.,d' was linear with the frequency difference between...
متن کاملThe Psychometric Function I
The psychometric function relates an observer's performance to an independent variable, usually some physical quantity of a stimulus in a psychophysical task. This paper, together with its companion paper (Wichmann & Hill 2000), describes an integrated approach to (1) fitting psychometric functions, (2) assessing the goodness-of-fit, and (3) providing confidence intervals for the function’s par...
متن کاملAmbient odour testing of concentrated animal feeding operations using field and laboratory olfactometers.
The Missouri Air Conservation Commission regulations include regulations that limit the amount of acceptable odor from confined animal feeding operations (CAFOs). The regulations concerning odor designate the use of a scentometer as a screening tool. The rules dictate that if an odor is detectable by an investigator at a dilution ratio of 5.4 using a scentometer then an air sample should be col...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemical senses
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2014