Role of Enhanced Visibility in Evaluating Polyposis Syndromes Using a Newly Developed Contrast Image Capsule Endoscope

نویسندگان

  • Ken Hatogai
  • Naoki Hosoe
  • Hiroyuki Imaeda
  • Jean-François Rey
  • Sawako Okada
  • Yuka Ishibashi
  • Kayoko Kimura
  • Kazuaki Yoneno
  • Shingo Usui
  • Yosuke Ida
  • Nobuhiro Tsukada
  • Takanori Kanai
  • Toshifumi Hibi
  • Haruhiko Ogata
چکیده

BACKGROUND/AIMS A flexible spectral imaging color enhancement system was installed in new capsule software for video capsule endoscopy. Contrast image capsule endoscopy (CICE) is a novel technology using light-emitting diodes selected for the main absorption range of hemoglobin. We assessed the feasibility and diagnostic effi cacy for small bowel surveillance in patients with polyposis syndromes. METHODS Six patients with polyposis syndromes, four with familial adenomatous polyposis and one each with Cowden syndrome (CS) and Cronkhite-Canada syndrome (CCS) were examined using CICE. We conducted three evaluations to assess the effect on the numbers of the detected polyps; compare polyp diagnostic rates between adenoma and hamartoma; and assess polyp visibility. RESULTS The numbers of detected polyps and diagnostic accuracy did not differ signifi cantly between pre-contrast and contrast images. However, 50% of the adenomatous polyps displayed enhanced visibility on contrast images. CICE contrast images exhibited clearly demarcated lesions and improved the visibility of minute structures of adenomatous polyps. Hamartomatous polyp micro-structures in patients with CS and CCS were more clearly visualized on contrast than pre-contrast images. CONCLUSIONS CICE is an effective tool for enhancing the visibility of polyps in patients with polyposis syndrome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Olympus capsule endoscopy for small bowel examination.

The video capsule endoscope has been developed to allow for direct examination of the small bowel in a safe, noninvasive and well-tolerated manner. The Olympus capsule endoscope, recently developed, with technology based on a charge-coupled device (CCD) and with electronic enhancement of image quality, differs from the Given capsule by a high-resolution CCD and an external real-time image viewe...

متن کامل

Image Enhancement Using an Adaptive Un-sharp Masking Method Considering the Gradient Variation

Technical limitations in image capturing usually impose defective, such as contrast degradation. There are different approaches to improve the contrast of an image. Among the exiting approaches, un-sharp masking is a popular method due to its simplicity in implementation and computation. There is an important parameter in un-sharp masking, named gain factor, which affects the quality of the enh...

متن کامل

A study of densitometry comparison among three radiographic processing solutions

ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

Magnified Examination of Small Colorectal Polyps Using a Prototype Electronic Endoscope

Magnifying electronic endoscopes are frequently used to evaluate the pit patterns of the colorectal mucosa, but such endoscopes suffer from a number of problems. For example, they tend to have long, hard tips and heavy controller sections. In addition, the magnified endoscopic images obtained are often quite coarse due to the small number of pixels in the charge-coupled device (CCD). As a resul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012