A randomized control trial evaluating fluorescent ink versus dark ink tattoos for breast radiotherapy

نویسندگان

  • Steven J Landeg
  • Anna M Kirby
  • Steven F Lee
  • Freddie Bartlett
  • Kumud Titmarsh
  • Ellen Donovan
  • Clare L Griffin
  • Lone Gothard
  • Imogen Locke
  • Helen A McNair
چکیده

OBJECTIVE The purpose of this UK study was to evaluate interfraction reproducibility and body image score when using ultraviolet (UV) tattoos (not visible in ambient lighting) for external references during breast/chest wall radiotherapy and compare with conventional dark ink. METHODS In this non-blinded, single-centre, parallel group, randomized control trial, patients were allocated to receive either conventional dark ink or UV ink tattoos using computer-generated random blocks. Participant assignment was not masked. Systematic (∑) and random (σ) setup errors were determined using electronic portal images. Body image questionnaires were completed at pre-treatment, 1 month and 6 months to determine the impact of tattoo type on body image. The primary end point was to determine that UV tattoo random error (σsetup) was no less accurate than with conventional dark ink tattoos, i.e. <2.8 mm. RESULTS 46 patients were randomized to receive conventional dark or UV ink tattoos. 45 patients completed treatment (UV: n = 23, dark: n = 22). σsetup for the UV tattoo group was <2.8 mm in the u and v directions (p = 0.001 and p = 0.009, respectively). A larger proportion of patients reported improvement in body image score in the UV tattoo group compared with the dark ink group at 1 month [56% (13/23) vs 14% (3/22), respectively] and 6 months [52% (11/21) vs 38% (8/21), respectively]. CONCLUSION UV tattoos were associated with interfraction setup reproducibility comparable with conventional dark ink. Patients reported a more favourable change in body image score up to 6 months following treatment. Advances in knowledge: This study is the first to evaluate UV tattoo external references in a randomized control trial.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast irradiation therapy innovations forgo permanent marks, minimize treatment.

Many women who had radiotherapy for breast cancer bear small, dark ink dots on their chest—a permanent reminder of diagnosis and treatment. Radiation oncologists use these to mark the area to irradiate. But many patients are reluctant to receive these permanent body markings, which can be visible in bathing suits and other clothing. Steven Landeg, M.Sc., senior radiographer, and colleagues at t...

متن کامل

Titanium, a major constituent of blue ink, causes resistance to Nd-YAG (1064 nm) laser: results of animal experiments.

A blue tattoo is more resistant to laser therapy than black or brown tattoos. This study aimed to confirm titanium as a key response-disturbing constituent in a blue tattoo ink after Nd-YAG (1064 nm) laser treatment by animal experiments. Rabbits' backs were tattooed with four ink colours, and the Nd-YAG (1064 nm) laser was used to remove the tattoos. The response to the laser treatment in the ...

متن کامل

Use of a novel shorter minimum caliber needle for creating endoscopic tattoos for preoperative localization: a comparative ex vivo study

BACKGROUND AND STUDY AIMS  In colorectal cancer surgery, inadvertent deep injections during endoscopic tattooing can cause India ink leakage into the peritoneum, leading to complications or to poor visualization of the surgical plane. This ex vivo animal study compared the use of novel shorter, minimum caliber needles versus conventional injection needles for endoscopic tattooing. ANIMALS AND...

متن کامل

Evaluating the Effect of Reactive Dye’s Structure and Penetrant Type on the Fastness of Ink-Jet Prints

The purpose of this study was to investigate the effect of the reactive dye structure and type of penetrant in ink formulation on paper ink-jet printing. Different type of papers, which have same grammage was printed upon with three commercial reactive dyes, CI Reactive Blue 49 Ink 1, 4, CI Reactive Blue 21 Ink 2, Ink 5 and CI Reactive Blue 19 Ink 3, Ink 6, which are based on different reactive...

متن کامل

Tattoo darkening and nonresponse after laser treatment: a possible role for titanium dioxide.

OBJECTIVE To examine relationships between chemical composition, biopsy findings, and clinical outcome in laser-treated tattoos. DESIGN Observational nonblinded retrospective study. SETTINGS University-based dermatology clinic and private practice. PARTICIPANTS Twenty patients who underwent biopsy of laser-treated tattoos. MAIN OUTCOME MEASURES Biopsy specimens were analyzed after laser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 89  شماره 

صفحات  -