Quantification of Absolute Myocardial Perfusion With Dynamic Positron Emission Tomography
نویسندگان
چکیده
Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided into eight sectors, and a small region of interest was assigned to the left ventricular blood pool to obtain the arterial input function. The net extraction of 13N ammonia was obtained for each sector by dividing the tissue 13N concentration at 10 minutes by the integral of the input function from the time of injection to 10 minutes. With this approach for calculating net extractions, rest and exercise net extractions were not significantly different from each other. To obviate possible overestimation of the true 13N ammonia input function by contamination by '3N-labeled compounds other than 13N ammonia or by spillover from myocardium into blood pool, the net extractions were calculated using only the first 90 seconds of the blood and tissue time-activity curves. This approach for calculating net extractions yielded significant differences between rest and exercise, with an average ratio of exercise to rest of 1.38+0.34. Nonetheless, the increase was less than predicted from the average 2.7-2.8-fold increase in double product at peak exercise or the 1.7-fold increase in double product at 1 minute after exercise. However, when the first 90 seconds of dynamic data were fit with a two compartment tracer kinetic model, average perfusion rates of 0.75+±0.43 ml/min/g at rest and 1.50± 0.74 ml/min/g with exercise were obtained. This average increase in perfussion of 2.2-fold corresponded to similar average increases in double product. Thus, the noninvasive technique of PET imaging with 13N ammonia shows promise for future applications in determining absolute flows in patients with coronary artery disease. (Circulation 1989;80:1328-1337)
منابع مشابه
Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography.
Positron emission tomography offers the ability to noninvasively assess regional myocardial perfusion in absolute terms (i.e., milliliters per gram per minute). Accurate estimates have been difficult to achieve with generator-produced 82Rb because of the complex behavior of this tracer in the myocardium. The aim of the present study was to determine whether regional myocardial blood flow could ...
متن کاملAre coronary plaque characteristics on computed tomography angiography associated with myocardial perfusion?
Noninvasive quantification of myocardial perfusion in absolute terms has gained increasing interest recently. Although the technique has been available for 2 decades, only lately quantification has become feasible in clinical routine. This has been facilitated by wider clinical use of positron emission tomography (PET) in cardiac patients and the technical development of imaging cameras and sof...
متن کاملNoninvasive Quantification of Regional Myocardial Perfusion With Rubidium-82 and Positron Emission Tomography
Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...
متن کاملIntegration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.
In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, whic...
متن کاملNoninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model.
Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...
متن کاملQuantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography.
OBJECTIVES The aim of this study was to compare fully quantitative cardiovascular magnetic resonance (CMR) and positron emission tomography (PET) myocardial perfusion and myocardial perfusion reserve (MPR) measurements in patients with coronary artery disease (CAD). BACKGROUND Absolute quantification of myocardial perfusion and MPR with PET have proven diagnostic and prognostic roles in patie...
متن کامل