Two-parameter angular light scatter collection for microfluidic flow cytometry by unique waveguide structures

نویسندگان

  • Jessica Godin
  • Yu-Hwa Lo
چکیده

Waveguide numerical aperture restrictions and light-blocking elements are used to create a microfluidic cytometer with both illumination and two-parameter light scatter collection systems integrated on-chip. Good forward scatter coefficients of variation (9.7-18.3%) are achieved for polystyrene beads under a reasonably high flow rate (28 cm/s) using a greatly simplified optical system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated classification of bacterial particles in flow by multiangle scatter measurement and support vector machine classifier.

Biological microparticles, including bacteria, scatter light in all directions when illuminated. The complex scatter pattern is dependent on particle size, shape, refraction index, density, and morphology. Commercial flow cytometers allow measurement of scattered light intensity at forward and perpendicular (side) angles (2 degrees <or= theta(1) <or= 20 degrees and 70 degrees <or= theta(2) <or=...

متن کامل

Wide-field fluorescent microscopy and fluorescent imaging flow cytometry on a cell-phone.

Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools o...

متن کامل

Automated Microfluidic Blood Lysis Protocol for Enrichment of Circulating Nucleated Cells

In this report the protocol for an automated microfluidic blood lysis device is detailed. Circulating nucleated cells (CNCs), including leukocytes and endothelial cells, provide an ideal platform for an updated status on the immune condition of an individual. The microfluidic protocol allows for enrichment of CNCs without selective cell loss and sample preparation variability due to user-mediat...

متن کامل

Determining blood cell size using microfluidic hydrodynamics.

Microfluidic flow cytometers currently analyze far fewer parameters than conventional flow cytometry or fluorescence activated cell sorting (FACS) in order to minimize cost and complexity. There is a need for microfluidic devices that analyze more and or new cell parameters with compact and minimal means. Here we show a new and explicitly microfluidic parameter, "hydrodynamic" cell size, and co...

متن کامل

A miniaturized wide-angle 2D cytometer.

BACKGROUND We present an optical waveguide based cytometer that is capable of simultaneously collecting the light scattered by cells over a wide range of solid angles. Such comprehensive scattering data are a prerequisite for the microstructural characterization of cells. METHODS We use latex beads as cell mimics, and demonstrate the ability of this new cytometer to collect back-scattered lig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2010