Detecting large biomolecules from high-salt solutions by fused-droplet electrospray ionization mass spectrometry.
نویسندگان
چکیده
A novel fused-droplet electrospray ionization (FD-ESI) source was developed to generate peptide and protein ions. The sample solution was first ultrasonically nebulized to form fine aerosols. The aerosols were then purged into a glass reaction chamber via nitrogen. Charged methanol droplets were continuously generated through electrospraying the acidic methanol solution from a capillary, which was located at the center of the reaction chamber. As the sample aerosols entered the reaction chamber, they fused with the charged methanol droplets from which electrospray proceeded continuously. The mass spectra of peptide and protein that FD-ESI-MS produced were practically identical to those that conventional ESI-MS produced. However, FD-ESI-MS resulted in an extremely high salt tolerance. Cytochrome c ions were detected in the solutions that contained 10% (w/w; 1.709 M) NaCl or 2.5% (425 mM) NaH2PO4. As with those obtained from the solution that lacked NaCl and NaH2PO4, the width of cytochrome c ion peaks remained nearly unchanged.
منابع مشابه
A simplified electrospray ionization source based on electrostatic field induction for mass spectrometric analysis of droplet samples.
A simplified electrospray ionization source based on electrostatic field induction is introduced in this paper. The electrostatic field induced spray ionization, termed EFISI, is easily performed using a needle electrode and a capillary, and it does not require heat, gas, a syringe pump or any other equipment. A high voltage is applied to a needle electrode which does not contact the sample. Th...
متن کاملDroplet Analysis with Electrospray Ionization Mass Spec- Trometry Using an Integrated Glass Microchip
ABSTRACT We describe an integrated microchip for droplet analysis with electrospray ionization mass spectrometry (ESI-MS). The chip integrated multiple modules of droplet generator, droplet extraction interface, and monolithic ESI-emitter. A novel droplet extraction interface based on a hydrophilic tongue structure was developed to transfer droplet from segmented phase to aqueous phase with hig...
متن کاملNovel methods for manipulating ion types in the solution and gas phases for the structural analysis of biomolecules using Mass Spectrometry
Fisher, Christine M. Ph.D., Purdue University, May 2015. Novel Methods for Manipulating Ion Types in the Solution and Gas Phases for the Structural Analysis of Biomolecules Using Mass Spectrometry. Major Professor: Scott McLuckey. Mass Spectrometry has become a valuable tool for the analysis of a variety of molecules, making it applicable to many fields. The advent...
متن کاملDirect analysis of liquid samples by desorption electrospray ionization-mass spectrometry (DESI-MS).
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the direct analysis of liquid samples. Several interesting results were found. First, in contrast to the previous DESI analysis of dried solid samples that was limited to proteins with MW < or = 25 kDa (Anal. Chem. 2007, 79, 3514), bovine serum albumin (BSA, 66 kDa) was successfully ionized from solutions by DESI w...
متن کاملDesorption Electrospray Ionization (DESI)
A new method of desorption ionization is described and applied to the ionization of various compounds, including peptides and proteins present on metal, polymer, and mineral surfaces. Desorption electrospray ionization (DESI) is carried out by directing electrosprayed charged droplets and ions of solvent onto the surface to be analyzed. The resulting mass spectra are similar to normal ESI mass ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 74 11 شماره
صفحات -
تاریخ انتشار 2002