Appropriate patient instructions can reduce prostate motion

نویسندگان

  • Reinhold Graf
  • Dirk Boehmer
  • Jacek Nadobny
  • Volker Budach
  • Peter Wust
چکیده

BACKGROUND Interfraction prostate motion must be compensated by increased safety margins. If filling status of rectum and bladder is constant, motion should be reduced. We attempted to reduce interfraction motion errors by proper patient instruction. METHOD In 38 patients pairs of radio-opaque fiducial markers were implanted prior to definitive radiotherapy. Patients were positioned either according to skin marks or infrared body marker. We measured prostate displacement, i.e. pelvic bones versus intraprostatic marker position, via ExacTrac (two orthogonal radiographies) in 1252 fractions. Systematic and random setup and displacement errors were determined and safety margins estimated. RESULTS In our study interfraction prostate displacement is < 1 mm in RL direction, and < 2 mm in AP and SI direction. Systematic errors are slightly below random errors (< 1.5 mm). Positioning according skin marks results in higher inaccuracies of ±1.5 - 2 mm in RL and ±2 - 2.5 mm in AP/SI direction. CONCLUSIONS In case of appropriate patient instructions (constant organ filling) the positioning via bone fusion requires CTV-PTV margins of 2 mm in RL, 4 mm in AP, and 5 mm in SI direction. Studies without any description of patient instruction found much higher margins of > 1 cm in AP and SI direction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش مورد: سرطان پروستات

Background and Objective: Prostate cancer is reported to affect approximately 70% of men and is the second leading cause of death in men. An early diagnosis and screening can reduce the associated complications and mortality rate. Case Presentation: A 52-year-old man complaining of a backache for eight months reported to the hospital. The initial examination showed him to be suffering from an ...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.

PURPOSE The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. METHODS AND MATERIALS In this prospecti...

متن کامل

Contribution of 68Ga-PSMA PET/CT to targeting volume delineation of prostate cancer treated with conformal radiation therapy: Which SUV threshold is appropriate?

Introduction: Prostate-specific membrane antigen (PSMA) has been demonstrated as a promising tool for specific imaging of prostate cancer (PCa) via positron emission tomography-computed tomography (PET/CT) scanning. Radiation treatment planning (RTP) based on 68Ga-PSMA PET/CT scanning can also lead to some decision modifications.  The specific goal o...

متن کامل

Prostate IMRT: Two-dimensional model of rectal NTCP employing the variability of rectal motion and rectum wall thickness

Background: In order to improve the evaluation of possible rectal toxicity based on the rectal normal tissue complication probability (NTCP), we consider the fractional dependence of the NTCP on the wall thickness (tW) and rectal displacement (RM). Materials and Methods: The two-dimensional NTCP model (NTCP2D) was developed using radiotherapy plans of ten randomly selected patients with prostat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012