Ultrasound Measurements of the Distance between Limbus and Retinal Break in Eyes with Media Opacities.

نویسندگان

  • Agostino S Vaiano
  • Elisabet Coronado Quitllet
  • Gaetano Zinzanella
  • Giacomo De Benedetti
  • Guido Caramello
چکیده

PURPOSE To assess the reproducibility and accuracy of ultrasound (US) measurements in determining the distance between corneoscleral limbus and retinal break and its relation with the distance measured by indirect ophthalmoscopy, in patients undergoing a laser retinopexy procedure. METHODS Forty-four patients with a single retinal break, scheduled for laser a retinopexy procedure (26 phakic patients and 18 pseudophakic patients), underwent 5 repeated measurements by high-resolution US and 3 measurements (at the time of the laser procedure, 1 and 3 months) by indirect ophthalmoscopy with scleral indentation of the corneoscleral limbus-retinal break distance with a caliper. RESULTS In the phakic patients group, measurements ranged from 8.75 mm to 14.45 mm (12.56 ± 1.24, mean ± SD) and from 9.5 mm to 15 mm (12.35 ± 1.32) with US and indirect ophthalmoscopy, respectively. In the pseudophakic patients group, measurements ranged from 9.04 mm to 13.95 mm (11.88 ± 1.33) and from 8.5 mm to 13.2 mm (11.93 ± 0.99) with US and indirect ophthalmoscopy, respectively. The correlation coefficient was greater than 0.97. Measurement variability was very small. In phakic eyes, it was 0.13 ± 0.08 mm and 0.13 ± 0.07 mm with US and indirect ophthalmoscopy, respectively. In pseudophakic eyes, it was 0.12 ± 0.05 mm and 0.14 ± 0.05 mm with US and indirect ophthalmoscopy, respectively. US and indirect ophthalmoscopy measurements were not statistically different (Student's t-test, P = 1.71). The analysis of the variance among phakic and pseudophakic patients confirmed that measurements of the two groups do not differ significantly (Fisher's exact test, P = 0.16). The univariate analysis showed no significant difference in both US and indirect ophthalmoscopy measurements (ANOVA, P = 0.09) and between the two types of measurements and patient groups (ANOVA, P = 0.38). CONCLUSION This study suggests relevant accuracy and reliability of US readings and provides the possibility of using this technique for localizing tears in eyes with media opacities by identifying the meridian and corneoscleral limbus-retinal break distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion

Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...

متن کامل

مقایسه نتایج باکلینگ اسکلرا همراه و بدون رتینوپکسی و لیزر فتوکوآگولیشن در ترمیم انفصال رگماتوژن شبکیه

Introduction: There are different methods to repair retinal detachment. In this trial the retinopexy in repairmen of retinal regmatogenesis RD is compared with other methods in Qazvin Teaching Hospitals during 1993-2003. Methods: This out come study was conducted on 47 patients with S/B and retinal break cryopexy (group I) , 30 patients undergoing S/B with barrier laser photocoagulation around...

متن کامل

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

بررسی عوامل موثر در جداشدگی شبکیه پس از لیزر درمانی پیشگیرانه ضایعات شبکیه

 Prevention of rhegmatogenous retinal detachment (RD) in susceptable eyes is necessary. In order to evaluate the role of signs and symptoms of the treated eyes in preventing RD, this study performed in prophylactically laser treated (PLT) eyes in Rasul-e Akram Hospital from 1991 to 1999.  This is an exisiting data study from the records of the patients who underwent PLT around the retinal lesio...

متن کامل

Effect of Media Opacity on Retinal Nerve Fiber Layer Thickness Measurements by Optical Coherence Tomography

PURPOSE To assess the effect of ocular media opacity on retinal nerve fiber layer (RNFL) thickness measurements by optical coherence tomography (OCT). METHODS In this prospective, non-randomized clinical study, ocular examinations and OCT measurements were performed on 77 cataract patients, 80 laser refractive surgery patients and 90 patients whose signal strength on OCT was different on two ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Retina

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 2017