Simultaneous measurement of formic acid, methanol and ethanol in vitreous and blood samples of postmortem by headspace GC-FID

نویسندگان

  • Hamideh Ghorbani
  • Alireza Nezami
  • Behjat Sheikholeslami
  • Arya Hedjazi
  • Mahnaz Ahmadimanesh
چکیده

Background Formic acid (formate) is the main reason for toxicity and death through methanol poisoning. The simultaneous determination of methanol, ethanol, and formate in the body can help to discover the cause of death and is useful in the diagnosis of acute methanol poisoning. The measurement of formate is not yet available in Iran. With regard to the increasing rate of methanol poisoning and its related mortality in Iran, as well as the main role of formate in methanol poisoning, this study was designed to set up an analytical method for the concurrent determination of ethanol, methanol, and formate. Methods Following the modification of a previously developed gas chromatography method, vitreous and blood samples of 43 postmortem cases with a history of methanol intoxication were collected over a period of 2 years at the Legal Medicine Organization of Mashhad. Thereafter, ethanol, methanol, and formate concentrations were measured by headspace GC/FID. Formate esterification was performed by the methylation of formate with sulfuric acid and methanol. In order to confirm the esterification method for the production of methyl formate, we used gas chromatography with a mass detector (GC/MS) because of its higher sensitivity and accuracy. Furthermore, the correlations between formate and methanol concentrations in blood and vitreous samples, and between formate and methanol were investigated. Results A significant relationship was found only between methanol concentrations in blood and vitreous samples (P < 0.03). Conclusions In postmortems, with the passage of time since alcohol ingestion, the measurement of only methanol concentration cannot determine the degree of toxicity or the cause of death. Therefore, using the present analytical method and measurement of formic acid, we can estimate the degree of toxicity and cause of death.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative endogenous formate analysis in plasma using headspace gas chromatography without a headspace analyzer.

The objective was to develop a simple routine method for quantitative measurement of endogenous formic acid in plasma and whole blood using headspace gas chromatography-flame ionization detection. (GC-FID). Two-hundred microliters of sample was placed in a 1-mL glass vial. Fifty microliters of aqueous ethanol (10%) was added as an internal standard and a derivatizing agent. Ethylformate formati...

متن کامل

Evaluation of an onsite alcohol testing device for use in postmortem forensic toxicology.

The disposable QED saliva alcohol test provides a very simple, fast, and reliable means for quantitative onsite alcohol detection. The purpose of this study was to determine if the QED test would be a useful tool for the determination of postmortem ethanol levels in cases where a rapid result was needed. QED results were compared with ethanol levels determined by headspace GC analysis. Both sal...

متن کامل

Biochemical Markers of Acute and Chronic Ethanol Use: Forensic and Clinical Applications

Background: The analysis of ethanol in bio-samples is an important method for determination of acute alcohol use/abuse both in clinical and forensic toxicology. In forensic cases, it is known that micro-organisms involved in the postmortem putrefaction process can produce alcohol and when the body has been traumatized. In clinical setting, post-ingestion time has a critical role for determinati...

متن کامل

Interpretation of Ethanol Analysis in Postmortem Specimens

Since alcohol is a general central nervous system depressant, it affects the motor and cognitive performance. Alcohol abuse is a major cause of medical and social problems. Additionally, to determine cause of death in legal medicine centers, alcohol analysis is the most frequently performed test in forensic toxicology laboratories. Accurate interpretation of ethanol concentration at the time...

متن کامل

Ethanol Concentration and Its Correlation with CNS Suppressor Drugs in Postmortem Subjects

Background: Many studies have been done in order to interpret correctly the results of ethanol analysis and its related problems. Unfortunately, it was not easy to determine BAC rate, due to postmortem different conditions or personal and clinical differences in metabolism and excretion of ethanol. The time between death and autopsy, the environmental conditions (temperature and humidity) are i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018