Comparison between hand rasping and robotic milling for stem implantation in cementless total hip arthroplasty.

نویسندگان

  • Shunsaku Nishihara
  • Nobuhiko Sugano
  • Takashi Nishii
  • Hidenobu Miki
  • Nobuo Nakamura
  • Hideki Yoshikawa
چکیده

We evaluated the effects of conventional hand rasping and robotic milling on the clinical and radiographic results of cementless total hip arthroplasty, with the same computed tomography (CT)-based 3-dimensional preoperative planning using a ROBODOC workstation (Integrated Surgical Systems, Davis, Calif). The robotic milling group consisted of 78 hips, and the hand-rasping group 78 hips. The radiographic findings from the preoperative planning and postoperative CT data were evaluated using the most accurate CT images reconstructed by the ROBODOC workstation. The robotic milling group showed significant superior Merle D'Aubigne hip score at 2 years. In the robotic milling group, there were no intraoperative femoral fractures, and a radiographically superior implant fit was obtained. Hand rasping had the potential to cause intraoperative femoral fractures, undersizing of the stem, unexpectedly higher vertical seating, and unexpected femoral anteversion causing inferior implant fit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison between robotic-assisted and manual implantation of cementless total hip arthroplasty.

BACKGROUND The benefits of robotic techniques for implanting femoral components during THA are still controversial. QUESTIONS/PURPOSES The purpose of this study was to prospectively compare the results and complications of robotic-assisted and hand-rasping stem implantation techniques. METHOD The minimum followup was 5 years (mean, 67 months; range, 60-85 months). One hundred forty-six prim...

متن کامل

Effect of robotic milling on periprosthetic bone remodeling.

The ROBODOC system has provided better fit and fill of the stem and less destruction of the bony architecture than with manual surgery. These benefits might affect femoral periprosthetic bone remodeling. We evaluated the effects of robotic milling in cementless total hip arthroplasty (THA) in a longitudinal 24-month follow-up study using dual energy X-ray absorptiometry (DEXA) and plain radiogr...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 2006