A New Experimental Method for in Situ Corrosion Monitoring Under Alternate Wet-Dry Conditions
نویسندگان
چکیده
A new experimental method was applied in in situ corrosion monitoring of mild steel Q235 under alternate wet-dry conditions. The thickness of the electrolyte film during the wet cycle was monitored by a high-precision balance with a sensibility of 0.1 mg. At the same time, an electrochemical impedance technique was employed to study the effect of film thickness on corrosion rates. Experimental results showed that there was a critical electrolyte film condition for which the corrosion rate reached a maximum during wet-dry cycles. For the substrate, the critical condition could be described by a film thickness of about 17 μm. For the rusted specimen, the critical condition could be described by an electrolyte amount of about 0.038 g, which is equivalent to a film thickness of 38 μm. This monitoring system was very useful for studying atmospheric corrosion of metals covered by corrosion products.
منابع مشابه
Prevention of stack corrosion under wet flue gas desulfurization conditions in a coal-fired power plant: performance analysis and comparative study
Background: This study investigated the prevention of stack corrosion under wet flue gas desulfurization conditions in a coal-fired power plant. The performance analysis and comparative studies of six materials for the prevention of stack corrosion were investigated. Results: The ion chromatography analysis showed the acid condensation contained fluoride, chloride, nitrate, sulphate, and sulphi...
متن کاملA New Corrosion Sensor to Determine the Start and Development of Embedded Rebar Corrosion Process at Coastal Concrete
The corrosion of reinforcements induced by chloride has resulted to be one of the most frequent causes of their premature damage. Most corrosion sensors were designed to monitor corrosion state in concrete, such as Anode-Ladder-System and Corrowatch System, which are widely used to monitor chloride ingress in marine concrete. However, the monitoring principle of these corrosion sensors is based...
متن کاملElectrochemical Impedance Response of Zn and Galvanized Steel Corroding under Marine Atmospheric Environments
Impedance response of zinc and galvanized steel samples exposed in wet-dry cyclic condition using 0.05 M NaCl solution has been analyzed in order to evaluate their corrosion behavior. The wet-dry cyclic test was performed by exposing sample to alternate conditions of 1 h immersion in 0.05 M NaCl solution and 7 h drying at 298 K with relative humidity (RH) of 60% for 10 days consisting of 30 cyc...
متن کاملNew Insights in the Long-Term Atmospheric Corrosion Mechanisms of Low Alloy Steel Reinforcements of Cultural Heritage Buildings
Reinforcing clamps made of low alloy steel from the Metz cathedral and corroded outdoors during 500 years were studied by OM, FESEM/EDS, and micro-Raman spectroscopy. The corrosion product layer is constituted of a dual structure. The outer layer is mainly constituted of goethite and lepidocrocite embedding exogenous elements such as Ca and P. The inner layer is mainly constituted of ferrihydri...
متن کاملANOVELMONITORINGTECHNIQUE TO DEFINE CP CRITERIA FOR BURIED PIPELINES UNDER AC CORROSION CONDITION
Abstract: The risks of alternating current (AC) corrosion and overprotection increasingly demand new criteria forcathodically protected pipelines. To assess the risk of AC corrosion, new cathodic protection (CP) criteria have beenproposed based on DC/AC current densities measurements using coupons. The monitoring system designed for thisproject was based on the instant-off method, with steel co...
متن کامل