In Vivo Evaluation of Immediately Loaded Stainless Steel and Titanium Orthodontic Screws in a Growing Bone

نویسندگان

  • Kerstin Gritsch
  • Norbert Laroche
  • Jeanne-Marie Bonnet
  • Patrick Exbrayat
  • Laurent Morgon
  • Muriel Rabilloud
  • Brigitte Grosgogeat
چکیده

The present work intends to evaluate the use of immediate loaded orthodontic screws in a growing model, and to study the specific bone response. Thirty-two screws (half of stainless steel and half of titanium) were inserted in the alveolar bone of 8 growing pigs. The devices were immediately loaded with a 100 g orthodontic force. Two loading periods were assessed: 4 and 12 weeks. Both systems of screws were clinically assessed. Histological observations and histomorphometric analysis evaluated the percent of "bone-to-implant contact" and static and dynamic bone parameters in the vicinity of the devices (test zone) and in a bone area located 1.5 cm posterior to the devices (control zone). Both systems exhibit similar responses for the survival rate; 87.5% and 81.3% for stainless steel and titanium respectively (p = 0.64; 4-week period), and 62.5% and 50.0% for stainless steel and titanium respectively (p = 0.09; 12-week period). No significant differences between the devices were found regarding the percent of "bone-to-implant contact" (p = 0.1) or the static and dynamic bone parameters. However, the 5% threshold of "bone-to-implant contact" was obtained after 4 weeks with the stainless steel devices, leading to increased survival rate values. Bone in the vicinity of the miniscrew implants showed evidence of a significant increase in bone trabecular thickness when compared to bone in the control zone (p = 0.05). In our study, it is likely that increased trabecular thickness is a way for low density bone to respond to the stress induced by loading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Resolving Orthodontic Problems

Nowadays, with the advent of mini-implants, maximum anchorage has become possible and unwanted side effects have been reduced to a minimum. Mini-implants which are also known as Temporary Anchorage Devices (TADs) are small titanium bone screw or stainless steel bone screws which are placed either in buccal alveolar bone or the palatal side. These bone screws can be placed on the paramedian area...

متن کامل

The effect of the titanium nitride coating on bacterial adhesion on orthodontic stainless steel wires: in vivo study

The aim of the current study was an in vivo evaluation of the bacterial adhesion on TiN coated orthodontic stainless steel wires in 20 patients (age15-25) undergoing fi xed orthodontic treatment who have the indication for placement of 0.019 ×0.0 25 inch Stainless steel arch wires in both jaws. TiN coatings were formed on orthodontic stainless steel wires by physical vapor deposition (PVD), The...

متن کامل

Mechanical Evaluation of Stainless Steel and Titanium Dynamic Hip Screws for Trochanteric Fracture

This study aimed to present the mechanical performance evaluation of the dynamic hip screw (DHS) for trochanteric fracture by means of finite element method. The analyses were performed based on stainless steel and titanium implant material definitions at various stages of bone healing and including implant removal. The assessment of the mechanical performance used two parameters, von Mises str...

متن کامل

Late Removal of Titanium Hardware from the Elbow Is Problematic

A retrospective review of 21 patients that underwent bone screw removal from the elbow was studied in relation to the type of metal, duration of implantation, and the location of the screws about the elbow. Screw failure during extraction was the dependent variable. Five of 21 patients experienced hardware failure during extraction. Fourteen patients had titanium alloy implants. In four cases, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013