Missed breast cancer in two patients with prepectoral silicone gel breast implants following implant displacement mammography

نویسندگان

  • Walter Peters
  • Victor Fornasier
چکیده

Mammography is the primary method used for the early detection of breast cancer (1). In patients without breast implants, mammography usually involves two views in which the breast is compressed: a mediolateral oblique (MLO) view, where the breast is viewed from side to side, and a craniocaudal (CC) view, where the breast is viewed from top to bottom. The presence of silicone breast implants has been shown to interfere with complete imaging of the breast (2-9). Hayes and associates (4) showed that when standard compression views were used, a breast implant obscured 22% to 83% of visualizable breast tissue. To improve imaging in breast implant patients, Eklund et al (8) developed the implant displacement technique, in which the breast tissue is drawn anteriorly away from the implant and is compressed between the x-ray film holder and the paddle. When this technique was used in patients with breast implants and the results were compared with pre-augmentation films, the visualized area was still decreased, but only by 25% (5,6). Compression and displacement methods complement each other. Posterior breast tissue is visualized best with compression, and anterior tissue is seen best with displacement (7). Mammography centres currently recommend a four-view mammogram in patients with breast implants – the two standard compression views (MLO and CC) and the same views repeated using the implant displacement technique (10). The present report describes two patients who presented during the past year with a breast carcinoma that was missed following compression and displacement views and was discovered incidentally at the time of explantation of their implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cosmetic Case Report Rupture of a Hydrogel-Filled Breast Implant

In the early 1960s, Cronin and Gerow began to use a silicone bag filled with silicone gel for breast augmentation. Since then, researchers have been looking for different filler materials. An ideal prosthesis does not induce any tissue reaction, is stable, gives the breast a natural appearance, and is radiolucent during mammography. In case of rupture of the envelope, the filler material should...

متن کامل

Role of mammography to assess complications of silicone gel breast implants

W Peters, D Smith, H Grosman, V Fornasier. Role of mammography to assess complications of silicone gel breast implants. Can J Plast Surg 1995;3(3):150-156. Mammography is not accurate to predict implant rupture in most patients. Its sensitivity rate is only 11 to 16%. However, two mammographic findings appear to suggest implant rupture: the appearance of large areas of implant herniation, and t...

متن کامل

Breast phantom with silicone implant for evaluation in conventional mammography

With the increased incidence of cancer and a similarly increased number of surgeries for insertion of silicone breast implants, it is necessary to assess the effect of such material within the breast tissue, particularly in mammography, because of the reduction in the power of breast cancer diagnosis. In this work, we introduce a breast phantom with silicone implants in order to evaluate the in...

متن کامل

Migration of a Ruptured, Silicone Gel-Filled Breast Implant into Sternal and Abdominal Areas

Breast implants have been used for breast reconstruction and augmentation for the last 50 years. There are about 100,000 women in the United Kingdom with silicone implants, of which approximately 60% are for breast reconstruction following mastectomy [1]. Approximately one to two million women have undergone breast implantation in the United States [2]. The silicone Poly Implant Prothèse breast...

متن کامل

Evaluation of the Rupture of Silicone Breast Implants by Mammography

OBJECTIVE: The purpose of this study was to compare the efficacies of mammography, sonography and MR imaging in the detection of breast implant rupture of an asymptomatic population. MATERIALS AND METHODS: We prospectively evaluated 83 breast implants in 44 asymptomatic patients who subsequently had implants removed by a surgeon to determine sensitivity and specificity of mammography, ultrasono...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001