Fast 2D MRI acquisitions for motion correction in PET-MRI

نویسندگان

  • Michael Fieseler
  • Christopher Glielmi
  • Thomas Kösters
  • Lynn Frohwein
  • Fernado Boada
  • Xiaoyi Jiang
  • Klaus P Schäfers
چکیده

European Institute for Molecular Imaging, University of Münster, Münster, Germany We performed continuous, fast acquisitions of 2D MR slices covering the thorax under free breathing. In present work, acquired 2D stacks are re-stored using a respiration signal. The usage of 2D slices is similar to the method described in [1]. The proposed method, however, does not include a navigator and acquisition times are shorter. Dara were acquired from two patients on a Siemens Biograph mMR scanner (Siemens Healthcare, Erlangen, Germany) using a FLASH sequence, TE 1.38ms, TR 26ms, flip angle 12o, a 32-channel body-coil (acceleration factor of 8). 20 coronal slices were acquired with 3.9 x 6.25mm2 in-plane resolution (HF, LR), 128 x128 pixel, slice thickness 9mm, slice spacing 9mm, 26ms per 2D slice (total acquisition time 160s). A respiratory signal was estimated from affine registrations of an area showing respiratory motion and subsequently used to sort the acquired 2D stacks into 8 respiratory phases. Figure 1 shows input data and re-gated data. Noise is reduced by averaging of several 2D stacks. Additionally, cardiac motion is eliminated to a large extent, thus the generated dataset can be used for respiratory motion correction. Average correlation of 2D stacks assigned to a phase is 0.958 for dataset 1 (randomly selected gates: 0.933, SD 0.03). For dataset 2 the average correlation of 2D stacks assigned to a phase is 0.94 (randomly selected gates: 0.9, SD 0.036). The results indicate that the proposed method is suitable for use in respiratory motion correction of PET data. In future work we will evaluate our approach on more datasets. Additionally, we will use motion estimates for each acquired 2D image stack to correct motion frame-wise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

List-Mode Affine Rebinning for Respiratory Motion Correction in PET Cardiac Imaging

Positron Emission Tomography (PET) is an established functional imaging modality but its practical deployment is hampered by motion artefacts. This paper proposes a method for correcting reconstructed PET images through a list-mode rebinning process. Respiratory motion is compensated for by applying 2D affine transforms to the respiratory gated sequence of line-ofresponse events prior to image ...

متن کامل

Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI

University College London, London, UK Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and tracer quantification adversely affected due to count ‘smearing’. Motion correction by registration of PET gates becomes increasingly difficult with shorter scan times and less counts. The advent of simultaneous PET/MRI scanners allows the use of high spatial resolution...

متن کامل

MRI-based nonrigid motion correction in simultaneous PET/MRI.

UNLABELLED Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory mot...

متن کامل

A Novel Approach to High Resolution Fetal Brain MR Imaging

This paper describes a novel approach to forming high resolution MR images of the human fetal brain. It addresses the key problem of motion of the fetus by proposing a registration refined compounding of multiple sets of orthogonal fast 2D MRI slices, that are currently acquired for clinical studies, into a single high resolution MRI volume. A robust multi-resolution slice alignment is applied ...

متن کامل

Super-resolution Reconstruction of Fetal Brain MRI

Current fetal MRI practice involves fast 2D slice acquisitions. The reconstruction of volumetric fetal brain MRI from these acquisitions and its post-processing is greatly desired for studying in-utero brain development. The previously developed reconstruction techniques rely on iterations of slice-tovolume registration and scattered data interpolation. In contrast, the technique introduced her...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014