ar X iv : a st ro - p h / 01 11 03 1 v 1 1 N ov 2 00 1 Modeling Charge Transfer Inefficiency in the Chandra Advanced CCD Imaging Spectrometer

نویسنده

  • G. P. Garmire
چکیده

The front-illuminated (FI) CCDs in the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory (Chandra) were damaged in the extreme environment of the Earth’s radiation belts, causing charge traps that result in enhanced charge transfer inefficiency (CTI) during parallel readout. This causes row-dependent gain, event grade ‘morphing’ (spatial redistribution of charge) and energy resolution degradation. The ACIS back-illuminated (BI) CCDs also exhibit pronounced CTI due to their manufacturing. It is mild enough that position-dependent energy resolution is not seen, but it is present in both parallel and serial registers. This CTI also changes the gain and event grades, in a spatially complicated way as parallel and serial CTI interact. Given these realities, we have developed and tuned a phenomenological model of CTI for both FI and BI CCDs and incorporated it into our Monte Carlo simulations of the ACIS CCDs. It models charge loss and the spatial redistribution of charge (trailing), thus reproducing the spatially-dependent gain and grade distribution seen in all ACIS CCDs and the row-dependent energy resolution seen in the FI devices. Here we explore the evidence for CTI, compare our simulations to data, and present a technique for CTI correction based on forward modeling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : a st ro - p h / 04 07 19 9 v 1 9 J ul 2 00 4 A charge transfer inefficiency correction model for the Chandra Advanced CCD Imaging Spectrometer

Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of mag...

متن کامل

ar X iv : a st ro - p h / 01 11 00 3 v 1 3 1 O ct 2 00 1 Simulating CCDs for the Chandra Advanced CCD Imaging Spectrometer

We have implemented a Monte Carlo algorithm to model and predict the response of various kinds of CCDs to X-ray photons and minimally-ionizing particles and have applied this model to the CCDs in the Chandra X-ray Observatory's Advanced CCD Imaging Spectrometer. This algorithm draws on empirical results and predicts the response of all basic types of X-ray CCD devices. It relies on new solution...

متن کامل

ar X iv : a st ro - p h / 06 06 17 8 v 1 7 J un 2 00 6 Temperature dependence of charge transfer inefficiency in Chandra X - ray CCDs

Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of mag...

متن کامل

ar X iv : a st ro - p h / 04 11 16 2 v 1 8 N ov 2 00 4 Chandra observations of the recurrent nova IM Nor

The recurrent nova IM Nor was observed twice in X-rays with Chandra ACISS, 1 and 6 months after the optical outburst. It was not detected in the first

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001