Automatic nasal continuous positive airway pressure titration in the laboratory: patient outcomes.
نویسندگان
چکیده
BACKGROUND Manual titration of nasal continuous positive airway pressure (NCPAP) treatment for obstructive sleep apnoea (OSA) is time consuming and expensive. There are now "intelligent" NCPAP machines that try to find the ideal pressure for a patient by monitoring a combination of apnoeas, hypopnoeas, inspiratory flow limitation, and snoring. Although these machines usually find similar pressures to skilled technicians, it is not clear if their use in the sleep laboratory influences subsequent acceptance by patients. This study addresses this question. METHODS One hundred and twenty two patients undergoing a trial of NCPAP were randomly allocated to either manual or automatic (Horizon, DeVilbiss) titration of pressure during their first night on NCPAP in a hospital sleep laboratory. The primary outcome (available on 112 patients) was the acceptance of NCPAP or otherwise six weeks following the initial titration night. Baseline indicators of severity were compared between the groups, as were the pressures selected and the subsequent improvement in the sleepiness of the patients. RESULTS The initial severity of OSA was not significantly different in the two groups and the mean (SD) NCPAP pressures were similar (manual 8.7 (2.5) cm H2O, automatic 8.2 (2.1) cm H2O). The percentage of patients successfully established on CPAP at six weeks was 64% and 73% for the manual and automatic groups, respectively; 13% and 2%, respectively, in the manual and automatic groups had given up completely (p < 0.05), and there were about equal numbers (23% versus 25%) in the two groups who were still undecided. CONCLUSIONS The substitution of automatic NCPAP titration for manual titration during the first night of NCPAP in patients with OSA does not reduce the number accepting the treatment at six weeks and may slightly improve it. This has important cost saving potential.
منابع مشابه
Heated Humidified High-Flow Nasal Cannula Versus Nasal Continuous Positive Airway Pressure for the Facilitation of Extubation in Preterm Neonates with Respiratory Distress
Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity as an alternative to nasal continuous positive airway pressure (nCPAP) therapy in the management of preterm neonates with respiratory distress due to ease of administration and patient comfort. However, limited evidence is available addressing its risks and benefits. To study the efficacy and safety of HHHFNC i...
متن کاملComparison of Nasal Continuous Positive Airway Pressure Therapy with and without Prophylactic Surfactant in Preterm Neonates
Background: Preterm labor is at risk for respiratory distress syndrome (RDS) and sometimes requires to mechanical ventilation (MV) and surfactant therapy. Continuous positive airway pressure (CPAP) and Nasal Continuous positive airway pressure (NCPAP) are the methods of respiratory support especially for using in RDS of neonates. In other method surfactant is administered to babies via tracheal...
متن کاملSudden Complete Versus Gradual Weaning from Nasal Continuous Positive Airway Pressure in Preterm Neonates: A Randomized Controlled Trial
Background: Continuous positive airway pressure (CPAP) is used as respiratory support in preterm neonates; however, the best weaning method has not yet been determined. In this study, we compared sudden complete and gradual weaning from nasal CPAP (NCPAP) in preterm newborns. Methods: This randomized controlled trial was conducted on 62 prete...
متن کاملUse of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome.
Nasal symptoms associated with the use of nasal continuous positive airway pressure (nCPAP) in obstructive sleep apnoea (OSA) can adversely impact on patients' tolerance, acceptance and adherence to nCPAP therapy. Regular use of heated humidification is effective in alleviating these symptoms and improve patient comfort. In a randomised, parallel, double-blinded, controlled study, the present a...
متن کاملContinuous positive airway pressure titration for obstructive sleep apnoea: automatic versus manual titration.
BACKGROUND AND AIMS Manual laboratory continuous positive airway pressure (CPAP) titration for obstructive sleep apnoea (OSA) is costly, time intensive and delays access to treatment. Automatic positive airway pressure (APAP) titration has the potential to reduce cost and improve access to treatment. The aim of this study was to assess the clinical efficacy and costs of APAP titration compared ...