Expiratory flow limitation and intrinsic positive end-expiratory pressure in obesity.

نویسندگان

  • W Pankow
  • T Podszus
  • T Gutheil
  • T Penzel
  • J Peter
  • P Von Wichert
چکیده

Breathing at very low lung volumes might be affected by decreased expiratory airflow and air trapping. Our purpose was to detect expiratory flow limitation (EFL) and, as a consequence, intrinsic positive end-expiratory pressure (PEEPi) in grossly obese subjects (OS). Eight OS with a mean body mass index (BMI) of 44 +/- 5 kg/m2 and six age-matched normal-weight control subjects (CS) were studied in different body positions. Negative expiratory pressure (NEP) was used to determine EFL. In contrast to CS, EFL was found in two of eight OS in the upright position and in seven of eight OS in the supine position. Dynamic PEEPi and mean transdiaphragmatic pressure (mean Pdi) were measured in all six CS and in six of eight OS. In OS, PEEPi increased from 0.14 +/- 0.06 (SD) kPa in the upright position to 0.41 +/- 0.11 kPa in the supine position (P < 0.05) and decreased to 0.20 +/- 0.08 kPa in the right lateral position (P < 0.05, compared with supine), whereas, in CS, PEEPi was significantly smaller (<0.05 kPa) in each position. In OS, mean Pdi in each position was significantly larger compared with CS. Mean Pdi increased from 1.02 +/- 0.32 kPa in the upright position to 1.26 +/- 0.17 kPa in the supine position (not significant) and decreased to 1. 06 +/- 0.26 kPa in the right lateral position (P < 0.05, compared with supine), whereas there were no significant changes in CS. We conclude that in OS 1) tidal breathing can be affected by EFL and PEEPi; 2) EFL and PEEPi are promoted by the supine posture; and 3) the increased diaphragmatic load in the supine position is, in part, related to PEEPi.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brochard Intrinsic ( or auto - ) positive end - expiratory pressure during spontaneous or assisted ventilation

The mechanisms generating intrinsic or auto-positive end-expiratory pressure (PEEP) during controlled mechanical ventilation in a relaxed patient also occur during spontaneous breathing or when the patient triggers the ventilator during an assisted mode [1, 2]. These include an increased time constant for passive exhalation of the respiratory system, a short expiratory time resulting from a rel...

متن کامل

Heavy snoring with upper airway resistance syndrome may induce intrinsic positive end-expiratory pressure.

We studied eight heavy snorers with upper airway resistance syndrome to investigate potential effects of sleep on expiratory airway and lung resistance, intrinsic positive end-expiratory pressure, hyperinflation, and elastic inspiratory work of breathing (WOB). Wakefulness and non-rapid-eye-movement sleep with high- and with low-resistance inspiratory effort (H-RIE and L-RIE, respectively) were...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

"Pseudo auto-PEEP"? A new cause for discrepancy between the end-expiratory occlusion plateau pressure and airway opening pressure.

The purpose of this study is to describe an unexpected degree of differences between expiratory occlusion plateau pressure (EPO) and airway opening pressure (Pawo) measured level of intrinsic positive end-expiratory pressure above externally applied (auto-PEEP) that was found in six critically ill patients. In six patients (ten studies), the presence and degree of auto-PEEP found during the EPO...

متن کامل

Assessment of Factors Related to Auto-PEEP.

BACKGROUND Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. METHODS One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 85 4  شماره 

صفحات  -

تاریخ انتشار 1998