Motion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions.
نویسندگان
چکیده
This paper presents a three-dimensional method to reconstruct moving objects from cone-beam X-ray projections using an iterative reconstruction algorithm and a given motion vector field. For the image representation, adapted blobs are used, which can be implemented efficiently as basis functions. Iterative reconstruction requires the calculation of line integrals (forward projections) through the image volume, which are compared with the actual measurements to update the image volume. In the existence of a divergent motion vector field, a change in the volumes of the blobs has to be taken into account in the forward and backprojections. An efficient method to calculate the line integral through the adapted blobs is proposed. It solves the problem, how to compensate for the divergence in the motion vector field on a grid of basis functions. The method is evaluated on two phantoms, which are subject to three different known motions. Moreover, a motion-compensated filtered back-projection reconstruction method is used, and the reconstructed images are compared. Using the correct motion vector field with the iterative motion-compensated reconstruction, sharp images are obtained, with a quality that is significantly better than gated reconstructions.
منابع مشابه
Motion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT
A method for motion compensated iterative CT reconstruction of a cardiac region-of-interest is presented. The algorithm is an ordered subset maximum likelihood approach with spherically symmetric basis functions, and it uses an ECG for gating. Since the straightforward application of iterative methods to CT data has the drawback that a field-of-view has to be reconstructed, which covers the com...
متن کاملFully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac CT reconstruction.
PURPOSE Cardiac computed tomography is a rapidly emerging technique for noninvasive diagnosis of cardiovascular diseases. Nevertheless, the cardiac motion continues to be a limiting factor. Electrocardiogram-gated cardiac computed tomography reconstruction methods yield excellent results, but these are limited in their temporal resolution due to the mechanical movement of the gantry, and lead t...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملImproving iterative 4D CBCT through the use of motion information
In Image-Guided RadioTherapy (IGRT) of lung tumors, patients undergo a 4D CT, on the basis of which their treatment is planned. It is implicitely assumed that their breathing motion will not change much throughout the treatment, and remain close to what it was during the 4D CT acquisition. During the treatment, several cone beam CT acquisitions are performed, and used to re-position the patient...
متن کاملMotion-Compensated Cone Beam CT Using a Conjugate Gradient Least Squares Algorithm and EIT Imaging Motion Data
Cone Beam Computed Tomography (CBCT) is an imaging modality that has been used in image-guided radiation therapy (IGRT). For applications such as lung radiation therapy, CBCT images are greatly affected by the motion artefacts. This is mainly due to low temporal resolution of CBCT. Recently, a dual modality of Electrical Impedance Tomography (EIT) and CBCT has been proposed, in which the high t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 53 23 شماره
صفحات -
تاریخ انتشار 2008