Achievement of Quality Control Parameters for NIS Personal Thermoluminescence Dosimeter (TLD) System
نویسندگان
چکیده
This work intend to identify and follow up quality control parameters to improve thermoluminescence dosemeter (TLD) system used for personal dosimetry in ionizing radiation metrology laboratory (IRML). Characterization of personal dosimetry system has presented in terms of the stability of reader calibration factors, linearity of response for Cs as reference radiation source, energy and angular dependence. In this study the TLD cards type GN-6770 with holder type 8806 manufactured by Harshaw which contained three TLDs detectors were used as personal dosimeter. Radiation characteristics and calibration methods were given in terms of personal dose equivalents (Hp (10)) incident on the ISO calibration phantom (water slab phantom). The distribution of the element correction coefficients (ECC) for the total population of cards, stability of the average reader calibration factors (RCF), and linearity of the response to dosimeter were studied. It was observed that the distribution of ECC for total cards population follows a Gaussian shaped curve and that the uncertainty associated to the ECC of the field cards is 10.3%. Over the 5 years period, the annual RCF varied 1.3% which indicates reliability and stability of the reading system. The angular dependence of the dosimeter was determined, using X-ray, γ-rays from Cs and Co sources [ISO 4037], at the angles of 0◦, ±30◦ and ±60◦. Further studies should be conducted in order to implement correction factors for supralinearity and different energies measurement. A correction factor needs to be implemented or the dosimeter modified (changes in holder filtration or another sensitive element) to meet the national requirement in the field of neutron dosimetry.
منابع مشابه
Recovery of thermoluminescence sensitivity in CaF2:Mn (TLD-400) dosimeter under heating process
In order to recovery the thermoluminescence (TL) sensitivity of CaF2:Mn (TLD-400) thermoluminescent dosimeter it was exposed to high gamma radiation dose of 10kGy, then by applying standard annealing followed by irradiation to 1Gy gamma dose, the TL signal was recorded . The TL response reduced due to the damage effect of high dose irradiation in comparison with control dosimeter with received ...
متن کاملReview of Methods for Determining Glow Peak Kinetics Parameters of Thermoluminescence Dosemeters
In the field of thermoluminescence dosimetry the daily analysis of multi-peak glow curves includes computerized curve-fitting methods, the so-called deconvolutions. These are in need of restricting the kinetic parameters E and s in order to obtain physically relevant results. There have been suggested various methods for the determination of these kinetic parameters based on a theory treating s...
متن کاملEvaluation of the Entrance Skin Dose in Animals Undergoing Diagnostic Radiology Using LiF, Mg, Ti Thermoluminescence Dosimetry (TLD-100)
Introduction According to the International Commission on Radiological Protection publication numbers 60 and 21, the environmental control standards should ensure human and other species protection to a desirable degree. Since application of radiographic procedures in Veterinary Medicine has increased significantly, in this study, we aimed to evaluate the entrance skin dose to the animals (e.g....
متن کاملInvestigation of neutron flux by thermoluminescence dosimeters in the neutron-gamma mixed field
Introduction: Neutrons have many applications in various fields, such as medicine. The important application of neutron in medical science is in Boron Neutron Capture Therapy (BNCT). Because of this, determination of neutron dose and flux is critical for the health maintaining of workers and patients exposed to this beam. The neutron radioisotope sources produce gamma rays in ...
متن کاملDental tissue as a TLD dosimeter
Background: Thermoluminescence dosimetry is one of the dosimetry procedures used widely as routine and personal dosimeters. In order to extend this kind of dosimeters, dental tissue has been examined and was found promising as a TLD dosimeter. Materials and Methods : In this study, 70 health teeth were collected. The only criterion, which was considered for selection of the teeth, was the healt...
متن کامل