Performance verification and comparison of TianLong automatic hypersensitive hepatitis B virus DNA quantification system with Roche CAP/CTM system
نویسندگان
چکیده
AIM To investigate and compare the analytical and clinical performance of TianLong automatic hypersensitive hepatitis B virus (HBV) DNA quantification system and Roche CAP/CTM system. METHODS Two hundred blood samples for HBV DNA testing, HBV-DNA negative samples and high-titer HBV-DNA mixture samples were collected and prepared. National standard materials for serum HBV and a worldwide HBV DNA panel were employed for performance verification. The analytical performance, such as limit of detection, limit of quantification, accuracy, precision, reproducibility, linearity, genotype coverage and cross-contamination, was determined using the TianLong automatic hypersensitive HBV DNA quantification system (TL system). Correlation and Bland-Altman plot analyses were carried out to compare the clinical performance of the TL system assay and the CAP/CTM system. RESULTS The detection limit of the TL system was 10 IU/mL, and its limit of quantification was 30 IU/mL. The differences between the expected and tested concentrations of the national standards were less than ± 0.4 Log10 IU/mL, which showed high accuracy of the system. Results of the precision, reproducibility and linearity tests showed that the multiple test coefficient of variation (CV) of the same sample was less than 5% for 102-106 IU/mL; and for 30-108 IU/mL, the linear correlation coefficient r2 = 0.99. The TL system detected HBV DNA (A-H) genotypes and there was no cross-contamination during the "checkerboard" test. When compared with the CAP/CTM assay, the two assays showed 100% consistency in both negative and positive sample results (15 negative samples and 185 positive samples). No statistical differences between the two assays in the HBV DNA quantification values were observed (P > 0.05). Correlation analysis indicated a significant correlation between the two assays, r2 = 0.9774. The Bland-Altman plot analysis showed that 98.9% of the positive data were within the 95% acceptable range, and the maximum difference was -0.49. CONCLUSION The TL system has good analytical performance, and exhibits good agreement with the CAP/CTM system in clinical performance.
منابع مشابه
Performance evaluation of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, version 2.0, for detection and quantification of hepatitis C virus RNA.
To evaluate the analytical performance and explore the clinical applicability of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, v2.0 (CAP/CTM v2.0), a platform comparison was performed on panels and diagnostic samples with the Roche cobas AmpliPrep/cobas TaqMan HCV test (CAP/CTM v1.0), the Siemens Versant HCV RNA 3.0 branched DNA (bDNA) test, the Abbott m2000 RealTime HCV assay (Realtime ...
متن کاملComparison of the Cobas Ampliprep/Cobas TaqMan HBV Test versus the Cobas Amplicor HBV monitor for HBV-DNA detection and quantification during antiviral therapy.
Performances of the new automatic system COBAS AmpliPrep/COBAS TaqMan 48 (CAP/CTM) (Roche, Branchburg, NJ) for HBV DNA extraction and real-time PCR quantification were assessed and compared with the endpoint PCR COBAS AMPLICOR HBV Monitor (CAHBM, Roche). Analytical evaluation with proficiency panels from UK National External Quality Assessment Scheme (UK NEQAS) over a 1-year period of distribut...
متن کاملCOBAS AmpliPrep-COBAS TaqMan hepatitis B virus (HBV) test: a novel automated real-time PCR assay for quantification of HBV DNA in plasma.
Success in antiviral therapy for chronic hepatitis B is supported by highly sensitive PCR-based assays for hepatitis B virus (HBV) DNA. Nucleic acid extraction from biologic specimens is technically demanding, and reliable PCR results depend on it. The performances of the fully automatic system COBAS AmpliPrep-COBAS TaqMan 48 (CAP-CTM; Roche, Branchburg, NJ) for HBV DNA extraction and real-time...
متن کاملComparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients
BACKGROUND Hepatitis B virus DNA quantification is essential for managing chronic hepatitis B (CHB). We compared the performance of artus HBV QS-RGQ (QIAGEN GmbH, Germany) and CAP/CTM v2.0 HBV assays (Roche Molecular Diagnostics, USA) in CHB patients. METHODS A comparative evaluation between two assays was performed with 508 clinical serum samples. Precision, linearity, and the limit of detec...
متن کاملComparison of conventional PCR with real-time PCR and branched DNA-based assays for hepatitis C virus RNA quantification and clinical significance for genotypes 1 to 5.
The key parameter for diagnosis and management of hepatitis C virus (HCV) infection is HCV RNA. Standardization of HCV RNA assays to IU is mainly based on genotype 1 panels. Little is known about the variability of commercially available HCV RNA assays for quantification of different genotypes. Two real-time reverse transcription (RT)-PCR assays (COBAS TaqMan HCV Test for use with the High-Pure...