Visualization of brain perfusion with harmonic gray scale and power doppler technology : an animal pilot study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE It is unclear which harmonic imaging mode (power Doppler or gray-scale imaging) is superior and which measuring method is the most robust for the description of brain perfusion. METHODS We performed an animal study on 6 beagles through the intact skull using a SONOS 5500 device and Optison injected intravenously in 3 different doses (0.15, 0.3, and 0.6 mL). Intensity versus heart-cycle plots for the brain parenchyma and the basal cerebral arteries were generated to evaluate the peak increase (PI) from baseline and the area under the curve (AUC). RESULTS With harmonic gray-scale imaging, a homogeneous increase in echo contrast of the brain parenchyma was observed. The effect was dose dependent, resulting in a significant increase in PI as well as an insignificant increase of the AUC with 0.3 mL versus 0.15 mL contrast agent (P=0.03 and P=0.65, respectively; n=5). With harmonic power Doppler, injection of the 3 different doses resulted in a nonsignificant increase in PI and AUC P=0.17, n=6 for both). After normalization of the brain signal to the peak arterial signal in individual dogs, a significant increase could be demonstrated (P=0. 03 and P=0.01, respectively; n=6). The signal pattern of harmonic power Doppler was inhomogeneous, with stronger signal increases in the anterior part of the brain. CONCLUSIONS Gray-scale imaging leads to a more homogeneous increase in echo contrast of the brain tissue and may be more suitable for displaying brain perfusion. The PI of the signal intensity seems the most robust parameter for the description of cerebral perfusion with both imaging modes under investigation.
منابع مشابه
Comparison of transcranial brain tissue perfusion images between ultraharmonic, second harmonic, and power harmonic imaging.
BACKGROUND AND PURPOSE To clarify optimal brain tissue perfusion images visualized by transcranial ultrasound harmonic imaging, we compared gray-scale integrated backscatter (IBS) images of new ultraharmonic imaging (UHI) and conventional second harmonic imaging (SHI) with power harmonic imaging (PHI) (harmonic B-mode with harmonic power Doppler images) in 10 patients with and 4 without a tempo...
متن کاملUltrasound perfusion imaging of the human brain.
BACKGROUND AND PURPOSE Color-coded perfusion maps can be calculated from ultrasound harmonic gray-scale imaging data to analyze brain tissue perfusion. METHODS In 13 healthy volunteers, 2 doses (0.5 and 1.5 mL) of Optison, a perfluoropropane-containing ultrasound contrast agent, were injected intravenously, and they produced a strong increase in echo enhancement in the brain parenchyma. The c...
متن کاملHarmonic imaging of the human brain. Visualization of brain perfusion with ultrasound.
BACKGROUND AND PURPOSE Through harmonic gray-scale imaging, it is possible to analyze brain tissue perfusion with different ultrasound methods. METHODS In 12 healthy volunteers, 2 doses (0.5 and 1.5 mL) of Optison, a perfluoropropane-containing contrast agent, were injected intravenously and produced a strong increase of brightness in the brain parenchyma. We used harmonic imaging for quantif...
متن کاملEffect of power Doppler and digital subtraction techniques on the comparison of myocardial contrast echocardiography with SPECT.
OBJECTIVE To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. DESIGN Cohort study. SETTING Regional cardiothoracic unit. PATIENTS 49 patients (mean (SD) age 61 (11) years; 27 women, ...
متن کاملTranslation of Methdology used in Human Myocardial Imaging to a Sheep Model of Acute Myocardial Infarction
Background: Pre-clinical investigation of stem cells for repairing damaged myocardium predominantly used rodents, however large animals have cardiac circulation closely resembling the human heart. The aim of this study was to evaluate whether SPECT/CT myocardial perfusion imaging (MPI) could be used for assessing sheep myocardium following an acute myocardial infarction (MI) and response to int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 31 7 شماره
صفحات -
تاریخ انتشار 2000