Design and Characteristics of a metamaterial transmit/receive coil element for 7 Tesla MRI

نویسندگان

  • J. Mosig
  • A. Bahr
  • T. Bolz
  • A. Rennings
چکیده

In this work the usage of a composite right/lefthanded (CRLH) metamaterial transmission line resonator as a transmit/receive coil for 7 Tesla magnetic resonance imaging (MRI) is investigated. On the basis of zeroth-order resonant antennas (ZORAs) a zeroth-order resonant coil (ZORC) was designed. Due to a constant current distribution along the element, a homogenous magnetic field is achieved in a larger area compared to a conventional microstrip transmission line (MTL) element. Numerical and experimental results are presented. Keywords— metamaterial, CRLH, MRI, ZORA, ZORC

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

T2-weighted prostate MRI at 7 Tesla using a simplified external transmit-receive coil array: correlation with radical prostatectomy findings in two prostate cancer patients.

PURPOSE To report design of a simplified external transmit-receive coil array for 7 Tesla (T) prostate MRI, including demonstration of the array for tumor localization using T2-weighted imaging (T2WI) at 7T before prostatectomy. MATERIALS AND METHODS Following simulations of transmitter designs not requiring parallel transmission or radiofrequency-shimming, a coil array was constructed using ...

متن کامل

Transmit and receive FDTD modeling as a valuable tool for RF coil development: validation of simulations with in vivo torso imaging at 7 Tesla

The ability to predict both transmit and receive characteristics in vivo is an important and necessary tool for the development of coils especially at ultra high magnetic fields (UHF). Accurate simulation permits the virtual development of coils saving both human and material resources [1, 2]. This is especially important during this period where large arrays and complex geometries are being pr...

متن کامل

A Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T

PURPOSE To design, construct and validate radiofrequency (RF) transmit and receive phased array coils for high-resolution visual cortex imaging at 7 Tesla. METHODS A 4 channel transmit and 16 channel receive array was constructed on a conformal polycarbonate former. Transmit field efficiency and homogeneity were simulated and validated, along with the Specific Absorption Rate, using [Formula:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009