A novel Schlemm's Canal scaffold increases outflow facility in a human anterior segment perfusion model.

نویسندگان

  • Lucinda J Camras
  • Fan Yuan
  • Shan Fan
  • Thomas W Samuelson
  • Ike K Ahmed
  • Andrew T Schieber
  • Carol B Toris
چکیده

PURPOSE An intracanalicular scaffold (Hydrus microstent) designed to reduce intraocular pressure as a glaucoma treatment was tested in human anterior segments to determine changes in outflow facility (C). METHODS Human eyes with no history of ocular disease or surgeries were perfused within 49 hours of death. The anterior segments were isolated and connected to a perfusion system. Flow rates were measured at pressures of 10, 20, 30, and 40 mm Hg. The scaffold was inserted into Schlemm's canal of the experimental eye, while a control eye underwent a sham procedure. Flow rate measurements were repeated at the four pressure levels. Individual C values were computed by dividing the flow rate by its corresponding pressure, and by averaging the four individual C measurements. The change in C between control and experimental eyes was assessed by the ratio of the baseline and second C measurement. In two eyes, the placement of the scaffold was evaluated histologically. RESULTS After scaffold implantation in the experimental eyes, the average C increased significantly from baseline (n = 9, P < 0.05). Ratios of C at all pressure levels, except for 10 mm Hg, were significantly higher in experimental eyes (n = 9) than control eyes (P < 0.05, n = 7). Histologically, the scaffold dilated Schlemm's canal with no visible damage to the trabecular meshwork. CONCLUSIONS The Hydrus Microstent provided an effective way to increase outflow facility in human eyes ex vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement in outflow facility by two novel microinvasive glaucoma surgery implants.

PURPOSE To determine improvement in outflow facility (C) in human anterior segments implanted with a novel Schlemm's canal scaffold or two trabecular micro-bypasses. METHODS Human anterior segments were isolated from 12 pairs of eyes from donors with no history of ocular disease and then perfused at 50, 40, 30, 20, and 10 mm Hg pressures for 10 minutes each. Baseline C was calculated from per...

متن کامل

A novel 8-mm Schlemm's canal scaffold reduces outflow resistance in a human anterior segment perfusion model.

PURPOSE To study the effect on outflow facility and outflow resistance of a nitinol microstent implanted into Schlemm's canal. METHODS Using a constant pressure perfusion method, outflow facility and outflow resistance were measured in 26 pairs of dissected anterior segments from donated human eyes. Measurements were made at perfusion pressures of 10, 20, 30 and 40 mm Hg. The Hydrus Microsten...

متن کامل

Effect of heparin II domain of fibronectin on aqueous outflow in cultured anterior segments of human eyes.

PURPOSE To determine whether an integrin/syndecan-binding domain of fibronectin, called the heparin II (Hep II) domain, affects outflow facility in the human eye. METHODS Anterior segments of human eyes were placed in perfusion organ culture. One eye of each pair received the Hep II domain, and the fellow eye received DMEM or a heat-denatured Hep II domain. The Hep II domain was produced as a...

متن کامل

The effect of cytochalasin D on outflow facility and the trabecular meshwork of the human eye in perfusion organ culture.

PURPOSE To determine the effect of cytochalasin D on outflow facility in the human anterior segment, and the histologic changes that accompany the effect. METHODS Human anterior segments were studied in perfusion organ culture. The anterior segment from one eye received cytochalasin D, and that from the fellow control eye received vehicle; doses ranged from 0.06 mg/ml to 27.7 mg/ml. The durat...

متن کامل

Effects of latrunculin-B on outflow facility and trabecular meshwork structure in human eyes.

PURPOSE To determine the effect of the F-actin-disrupting agent latrunculin-B on aqueous outflow facility and trabecular meshwork architecture in human eyes. METHODS After baseline facility measurement in human eye bank eyes (n = 9 pairs), one eye of each pair received anterior chamber exchange and continued perfusion with medium containing 1 microM latrunculin-B. Contralateral eyes were trea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 10  شماره 

صفحات  -

تاریخ انتشار 2012