Persistent Hypotony Associated with Immunosuppressive Therapy in Glaucoma Drainage Implant Surgery

نویسندگان

  • Susana Duch
  • Elena Milla
  • Oana Stirbu
  • David Andreu
چکیده

PURPOSE To describe the histopathology of non-valved implant capsules in three cases of persistent postoperative hypotony after the restrictive tube ligature was released in patients receiving immunosuppressive therapy. OBSERVATIONS The macroscopic appearance of the capsules 3 and 4 months postoperatively was immature and loose. Microscopic examination disclosed extremely irregular thin tissue, with thicknesses ranging from 0.02 to 0.6 mm, depending on the capsular location studied. Withdrawal of immunosuppressive therapy did not facilitate rebuilding of new capsules. Replacement with a valved implant device was necessary in two cases; the third case recovered with tapering of prednisone. CONCLUSIONS AND IMPORTANCE The use of chronic systemic immunosuppressive therapy might interfere with capsular formation around the plates of drainage devices inducing persistent hypotony. In these cases, the use of valved implants might be safer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaucoma drainage implants: a critical comparison of types.

PURPOSE OF REVIEW The purpose of this review is to critically compare the various glaucoma drainage implants in popular use. RECENT FINDINGS Glaucoma drainage implants are being increasingly utilized in the surgical management of glaucoma. Comparisons between the various drainage implants are difficult because most clinical data are derived from retrospective studies with different study popu...

متن کامل

Quarter-Shifted Microincisional Sutureless Vitrectomy in Patients with a Glaucoma Drainage Implant or Filtering Bleb

When vitrectomy is performed in eyes that have undergone glaucoma surgery, the site of sclerotomy often overlaps with the previous glaucoma operation site. It can lead to serious complications such as postoperative hypotony, leakage, and/or infection. Our technique involves modification of surgeon's position and two sclerotomy sites 45° away from the original position, with an infusion cannula ...

متن کامل

Five-year treatment outcomes in the Ahmed Baerveldt comparison study.

PURPOSE To compare the 5-year outcomes of the Ahmed FP7 Glaucoma Valve (AGV) (New World Medical, Cucamonga, CA) and the Baerveldt 101-350 Glaucoma Implant (BGI) (Abbott Medical Optics, Abbott Park, IL) for the treatment of refractory glaucoma. DESIGN Multicenter, randomized, controlled clinical trial. PARTICIPANTS A total of 276 patients, including 143 in the AGV group and 133 in the BGI gr...

متن کامل

Long-term evaluation of efficacy and safety of deep sclerectomy in uveitic glaucoma.

PURPOSE To assess long-term efficacy and safety of deep sclerectomy (DS) in uveitic glaucoma. PATIENTS AND METHODS Thirty-three consecutive eyes (21 patients) with uveitic glaucoma underwent DS with mitomycin C and implant. Goniopuncture (GP) was done for uncontrolled postoperative intraocular pressure (IOP). RESULTS Mean (± SD) follow-up was 33.2 (± 19.8) months. IOP was reduced from a mea...

متن کامل

Motility disturbance due to true Tenon cyst in a child with a Baerveldt glaucoma drainage implant.

Epithelial ingrowth of the bleb cavity, a true Tenon cyst, is a rare complication of a glaucoma drainage implant. Previous cases have been associated with persistent bleb leak, and most have occurred in eyes with prior extraocular surgery. We describe a case of a true Tenon cyst causing strabismus and an elevated intraocular pressure that was successfully treated by surgical revision.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2016