Flexible endoscopy for pediatric tracheobronchial metallic stent placement, maintenance and long-term outcomes

نویسندگان

  • Wen-Jue Soong
  • Pei-Chen Tsao
  • Yu-Sheng Lee
  • Chia-Feng Yang
چکیده

OBJECTIVES To assess the placement, surveillance management and long-term outcomes of the tracheobronchial (TB) balloon expandable metallic stent (BEMS) managed by therapeutic flexible endoscopy (TFE). METHODS This is a retrospective review and analysis of all computerized medical records and related flexible endoscopy videos of pediatric patients who received TB BEMS during 20 years period, from January 1997 to December 2016. TFE techniques with forceps debridement, balloon dilatation and laser ablation were used to implant stents, perform regular surveillance, maintain their functions, and expand the diameters of BEMS. Short-length (30cm-36cm) endoscopes of OD 3.2mm to 5.0mm coupled with the noninvasive ventilation, without ventilation bag, mask or airway tube, supported the whole procedures. RESULTS 146 BEMS were implanted in 87 consecutive children, including 84 tracheal, 15 carinal and 47 bronchial stents. At the time of placement, the mean age was 35.6 ± 54.6 month-old (range 0.3-228) and the mean body weight was 13.9 ± 10.6 kg (range 2.2-60). Surveillance period was 9.4 ± 6.7 years (range, 0.3-18.0). Satisfactory clinical improvements were noted immediately in all but two patients. Seventy-two (82.8%) patients were still alive with stable respiratory status, except two patients necessitating TFE management every two months. Fifty-one stents, including 35 tracheal and 16 bronchial ones, were successfully retrieved mainly with rigid endoscopy. Implanted stents could be significantly (< .001) further expanded for growing TB lumens. The final stent diameters were positively correlated to the implanted duration. Altogether, 33 stents expired (15 patients), 51 were retrieved (40 patients), and 62 remained and functioning well (38 patients), with their mean duration of 7.4 ± 9.5, 34.9 ± 36.3 and 82.3 ± 62.5 months, respectively. CONCLUSION In pediatric patients, TFE with short-length scopes coupled with this NIV support has provided a safe, feasible and effective modality in placing and subsequently managing TB BEMS with acceptable long-term outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Covered metallic stent for ischemic hilar biliary stricture.

Compared with surgery, endoscopic treatment is safe and highly effective for a postoperative hilar benign bile duct stricture (BDS). However, the long-term outcome of conventional placement of a single biliary stent for hilar benign BDS is generally poor. Although the placement of multiple biliary stents is preferred, multiple stenting in a BDS is difficult. Alternatively, single or multiple st...

متن کامل

Self-Expandable Metallic Stent Placement in the Palliative Treatment of Malignant Obstruction of Gastric Outlet and Duodenum

BACKGROUND/AIMS To asses the usefulness of flexible metallic stents in the palliation of malignant obstruction of gastric outlet and duodenum. METHODS Retrospective review was performed between January 2006 and December 2011 in 30 patients. Thirty consecutive patients with obstruction of the gastric outlet underwent palliative treatment with self-expandable flexible metallic stents. Complicat...

متن کامل

Removal of metallic tracheobronchial stents in lung transplantation with flexible bronchoscopy

BACKGROUND Airway complications are among the most challenging problems after lung transplantation, and Self-Expandable Metallic Stents (SEMS) are used to treat airway complications such as stenosis or malacia at the bronchial anastomosis sites. Several transplantation centers are reluctant to use SEMS since their removal is sometimes needed and usually requires the use of rigid bronchoscopy un...

متن کامل

Self-expanding metallic stent placement with an exaggerated 5-cm proximal tumor covering for palliation of esophageal cancer

BACKGROUND The study aimed to evaluate the short- and long-term outcomes with a technique of self-expanding metallic stent insertion in palliative esophageal cancer patients. We hypothesized that a systematic attempt at exaggerated (5 cm) proximal tumor covering could prevent both stent migration and tumor overgrowth/undergrowth. METHODS We reviewed retrospectively all patients who underwent ...

متن کامل

Self-expandable metallic tracheobronchial stent insertion and endobronchial electrocautery with flexible bronchoscopy: preliminary results at a cancer center.

BACKGROUND AND PURPOSE Technical developments have facilitated the implantation of metallic stents and the use of endobronchial electrocautery through a flexible bronchoscope to reestablish airway patency in patients with airway obstruction. Their application in a 180-bed cancer center is described. PATIENTS AND METHODS From August 2000 to December 2001, 12 patients (2 women, 10 men, mean age...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018