Electrode contact impedance sensitivity to variations in geometry.

نویسندگان

  • Roberto Cardu
  • Philip H W Leong
  • Craig T Jin
  • Alistair McEwan
چکیده

Electrode contact impedance is a crucial factor in physiological measurements and can be an accuracy-limiting factor when performing electroencephalography and electrical impedance tomography. In this work, standard flat electrodes and micromachined multipoint spiked electrodes are characterized with a finite-element method electromagnetic solver and the dependence of the contact impedance on geometrical factors is explored. It is found that flat electrodes are sensitive to changes in the outer skin layer properties related to hydration and thickness, while spike electrodes are not. The impedance as a function of the effective contact area, number of spikes and penetration depth has also been studied and characterized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Signal Quality in Dry Electrode EEG and the Relation to Skin-electrode Contact Impedance Magnitude

Current EEG research approaches are focusing on developing new dry electrode EEG (electroencephalogram) systems providing a high enough signal quality for a wide range of applications. This study proposes several parameters for evaluating signal quality of dry electrodes and relates the results to skin-electrode contact impedance magnitude values. The EEG recordings of a Ag/AgCl pinned electrod...

متن کامل

The impact of electrode area, contact impedance and boundary shape on EIT images.

Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of these electrode properties have been investigated individually, this paper inves...

متن کامل

Developed endplate geometry for uniform contact pressure distribution over PEMFC active area

Contact resistance among the components of a polymer exchange membrane fuel cell (PEMFC) has a crucial effect on cell performance. The geometry of the endplate plays an essential role in the contact pressure distribution over the membrane electrode assembly (MEA) and the amount of contact resistance between plates. In this work, the effects of endplate geometry on the contact pressure distribut...

متن کامل

Analytical electric field and sensitivity analysis for two microfluidic impedance cytometer designs.

Microfabricated impedance cytometers have been developed to measure the electrical impedance of single biological particles at high speed. A general approach to analytically solve the electric field distributions for two different designs of cytometers: parallel facing electrodes and coplanar electrodes, using the Schwarz-Christoffel Mapping method is presented. Compared to previous analytical ...

متن کامل

Electrical impedance tomography with compensation for electrode positioning variations.

Ideally electrical impedance tomography (EIT) should not be oversensitive to electrode positions, but this conflicts with efforts to produce high-resolution images. Two procedures are presented that balance reducing the sensitivity to electrode position errors with generating practicable EIT images. The first provides a criterion based on electrode sensitivity for regularizing the reconstructio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 33 5  شماره 

صفحات  -

تاریخ انتشار 2012