Optic nerve sheath diameter and lumbar puncture opening pressure in nontrauma patients suspected of elevated intracranial pressure.
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to determine if patients with nontraumatic causes of elevated intracranial pressure (ICP) could be identified by ultrasound measurement of optic nerve sheath diameter (ONSD). It was hypothesized that an ONSD greater than or equal to 5 mm would identify patients with elevated ICP. METHOD This was a prospective observational trial comparing ONSD with ICP measured by opening pressure manometry on lumbar puncture (LP). The cohort consisted of a convenience sample of adult patients presenting to the emergency department, requiring LP. The ONSD measurement was performed before computed tomography and LP. The physician performing the LP was blinded to the result of the ONSD measurement. An opening pressure on manometry of greater than or equal to 20 cm H2O and an ONSD greater than or equal to 5 mm were considered elevated. RESULTS Fifty-one patients were included in our study, 24 (47%) with ICP greater than or equal to 20 cm H2O and 27 (53%) with ICP less than 20 cm H2O. The sensitivity of ONSD greater than or equal to 5 for identifying elevated ICP was 75% (95% confidence interval, 53%-90%) with specificity of 44% (25%-65%). The area under the receiver operator characteristic curve was 0.69 (0.54-0.84), suggesting a relationship between ONSD and ICP. CONCLUSION An ONSD greater than or equal to 5 mm was associated with elevated ICP in nontraumatic causes of elevated ICP. Although a relationship exists, a sensitivity of 75% does not make ONSD measurement an adequate screening examination for elevated ICP in this patient population.
منابع مشابه
Elevated Intracranial Pressure Diagnosis with Emergency Department Bedside Ocular Ultrasound
Bedside sonographic measurement of optic nerve sheath diameter can aid in the diagnosis of elevated intracranial pressure in the emergency department. This case report describes a 21-year-old female presenting with 4 months of mild headache and 2 weeks of recurrent, transient binocular vision loss. Though limited by patient discomfort, fundoscopic examination suggested the presence of blurred o...
متن کاملOptimal Optic Nerve Sheath Diameter Threshold for the Identification of Elevated Opening Pressure on Lumbar Puncture in a Chinese Population
Ultrasonography of the optic nerve sheath diameter (ONSD) is a non-invasive and rapid method that might be helpful in the identification of increased intracranial pressure (ICP). The use of an ONSD greater than 5 mm on ultrasound as an indicator of increased ICP in a Caucasian population has been studied. However, the cut-off point of this predictor in Chinese patients has not been established....
متن کاملOptic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure
A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches. The headaches were prolonged, generalised, and unusually severe for the patient. Examination revealed papilloedema. The patient's optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm. The patient subsequently had computed tomog...
متن کاملEffect of scuba-diving on optic nerve and sheath diameters
Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...
متن کاملAccuracy of Noninvasive Intraocular Pressure or Optic Nerve Sheath Diameter Measurements for Predicting Elevated Intracranial Pressure in Cryptococcal Meningitis
BACKGROUND Cryptococcal meningitis is associated with increased intracranial pressure (ICP). Therapeutic lumbar puncture (LP) is recommended when the initial ICP is >250 mm H2O, yet the availability of manometers in Africa is limited and not always used where available. We assessed whether intraocular pressure could be a noninvasive surrogate predictor to determine when additional therapeutic L...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of emergency medicine
دوره 32 12 شماره
صفحات -
تاریخ انتشار 2014