Evaluation of meniscal extrusion with posterior root disruption and repair using ultrasound.

نویسندگان

  • Grant Rowland
  • Damon Mar
  • Terence McIff
  • Joshua Nelson
چکیده

BACKGROUND Ultrasound techniques have been utilized for detection of discrete meniscus tears and extrusion. Meniscal extrusion is associated with increased contact pressure and decreased contact area contributing to the advancement of knee osteoarthritis. The purpose of this biomechanical study was to detect meniscal extrusion using a clinically available, portable ultrasound device. And further, to show that extent of injury and a weight-bearing state correlate with amount of extrusion. METHODS A portable, hand-held ultrasound was utilized to image the lateral meniscus in association with (1) an intact posterior root attachment, (2) a 50% cut, (3) a 100% cut, and (4) repaired posterior root attachment. Images were obtained in an unloaded condition, and again under a static, physiologic (70kg) axial load for above injury levels, and again following repair. RESULTS Significant differences in extrusion were noted between the intact and both the 50% cut (p=0.028) and 100% cut groups (p<0.001) all in the loaded position. No significant difference was found in extrusion between intact state and repaired posterior root in the axially loaded position (p=0.174). Both load (p=0.003) and injury level (p=0.005) had significant effects on the mean extrusion of the lateral meniscus. CONCLUSION Sectioning of the lateral meniscus posterior root will produce significantly increased lateral extrusion of the meniscus under physiologic loads. Unlike MRI evaluation, weight-bearing ultrasound images allow a functional assessment of meniscus extrusion. Trans-tibial posterior root repair can restore the lateral meniscus position and integrity. CLINICAL RELEVANCE This weight-bearing ultrasound technique can be an important assessment tool for complete evaluation of meniscus injuries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Meniscal Roots: Current Concepts Review

Meniscal root tears are defined as radial tears located within 1 cm from the meniscal attachment or a bony rootavulsion. This injury is biomechanically comparable to a total meniscectomy, leading to compromised hoop stressesresulting in decreased tibiofemoral contact area and increased contact pressures in the involved compartment.These changes are detrimental to the articular cartilage and ult...

متن کامل

Meniscal Extrusion in the Knee: Should only 3 mm Extrusion be Considered Significant? An Assessment by MRI and Arthroscopy

AIM The aim of this study was to assess whether significant meniscal extrusion of more than 3 mm or of even lesser degrees of extrusion could be considered significant. We also aimed to determine the morphology of tears that are most likely to be associated with significant extrusion. Study design and material. The study was done retrospectively on a group of 202 patients (157 males and 45 fema...

متن کامل

ARTHROSCOPIC MODIFIED ALL-INSIDE LATERAL MENISCAL TEAR REPAIR USING TWO POSTERIOR PORTAL TECHNICAL NOTE

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

Jaaos-d-14-00003 71..76

Posterior root avulsions of the medial and lateral menisci result in decreased areas of tibiofemoral contact and increased tibiofemoral contact pressures. These avulsions may lead to the development of osteoarthritis. Therefore, two surgical techniques, the transtibial pullout repairand thesutureanchor repair, have recentlybeendeveloped to restore the native structure and function of the menisc...

متن کامل

Loop-Post Construct, A Novel Technique for Medial Meniscus Root Repair

Surgical reattachment of medial meniscus posterior root tear (MMPRT) with transtibial sutures can delay the presenceof medial knee joint compartment osteoarthritis. Most suture configurations are placed five mm away from the tornmargin in the meniscal substance which is already degenerated and may decrease the pull out strengths of repairconstruct. The number of meniscus penet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Knee

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2016