Transient Currents in a Double Conductor Line above a Conducting Half-Space
نویسنده
چکیده
Transient eddy current problem is solved in the present paper by the method of the Laplace transform for the case of a double conductor line located parallel to a conducting half-space. The Fourier sine and cosine integral transforms are used in order to find the Laplace transform of the solution. The inverse Laplace transform of the solution is found in closed form. The integrated electromotive force per unit length of the double conductor line is calculated in the form of an improper integral. Keywords—Transient eddy currents, Laplace transform, double conductor line.
منابع مشابه
Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA
In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...
متن کاملApplication of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes
In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...
متن کاملRadial Temperature Distribution of Aaac Overhead Line in Stationary and Transient Conditions
Commonly, dynamic line rating (DLR) calculates conductor temperature with a basic energy balance equation, which assumes homogeneous conductor temperature. With this 0D temperature assumption, however, there is a risk that inner layers of the conductor might exceed the limit temperature, if the rating current approaches its ampacity. Since conductor overheating should be avoided for operational...
متن کاملNumerical Simulation of Electromagnetic Acoustic Transducer in the Time Domain
A novel multistage numerical modeling approach to simulate acoustic-wave generation and propagation of an electromagnetic acoustic transducer (EMAT) is presented. The model assumes a uniform static magnetic field in a conducting half-space. A meander coil winding situated above the half-space is driven by a transient high-frequency current pulse. The numerically computed eddy currents in the co...
متن کاملTime domain half-space dyadic Green’s functions for eddy-current calculations
The field due to an impulsive current dipole embedded in a half-space conductor adjoining a nonconducting half space is given by an exact solution of the quasistatic field equations. This solution has been used to construct a half-space dyadic Green’s function containing a term for an unbounded conductor plus terms representing the field reflected at the interface between conducting and noncond...
متن کامل