Cyclic voiding cystouretrography without the use of fluoroscopic monitoring.

نویسندگان

  • Alev Kadioglu
  • Ismail Mihmanli
  • Fatih Kantarci
  • Aylin Tekes
  • Omer Uysal
چکیده

PURPOSE To determine whether cyclic voiding cystourethrography (VCUG) examinations can be performed without using real-time fluoroscopic monitoring. MATERIALS AND METHODS VCUG examinations were performed in 209 children (133 girls and 76 boys). In each child, it was performed in a cyclic manner (three consecutive cycles) without using fluoroscopic monitoring and one radiograph was taken in each cycle of the examination. All patients were sedated by midazolam prior to examination. The degree of vesicoureteric reflux (VUR) was graded for each of the kidney ureter units (KUU) (total 418 KUU) separately. Statistical analysis included the comparison of the presence and absence of VUR and three ordinal-matched comparisons of each cycle. RESULTS VCUG was detected in 37.3% of the children (78/209) and 28.7% (120/418) of the KUU. The absence of or same degree of VUR in three consecutive cycles were obtained in 345 KUU and the agreement was calculated as 82.5%. The same degree and presence of reflux were found in 85 and 89 refluxing KUU, the same negative findings (absence of VUR) in 306 and 298 KUU, and discordant findings in 27 and 31 KUU (between the first and second and between first and third cycles), respectively. Therefore, the agreement was 93.5 and 92.5% between the first and second cycles (p=0.70) and between the first and the third cycles (p=0.15), respectively. CONCLUSION Both the cyclic nature of this study and the results indicated that VCUG without real-time fluoroscopic monitoring could be used where adequate fluoroscopic examination is not possible for children in whom VUR detection is necessary and impacts treatment. However, the responsibility of pediatric radiologist always must also include the task to provide proper equipment for imaging children with suspected VUR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional (2D), three-dimensional static (3D) and real-time (4D) contrast enhanced voiding urosonography (ceVUS) versus voiding cystourethrography (VCUG) in children with vesicoureteral reflux.

BACKGROUND Two-dimensional (2DUS) contrast enhanced voiding urosonography has been used in the diagnosis and treatment monitoring of the vesicoureteral reflux in children for over 15 years. The opportunity of performing this examination with the use of three-dimensional static (3DUS) and real-time (4DUS) techniques opens up new diagnostic horizons. OBJECTIVE To analyze if 3DUS/4DUS bring addi...

متن کامل

Voiding cystography practices and preferences of North American pediatric urologists.

PURPOSE Little consensus exists regarding the choice of a specific modality of voiding cystography in the evaluation and management of vesicoureteral reflux. We hypothesized that choices of pediatric urologists are based on technical factors of the studies themselves, as well as institutional factors unique to their hospital(s). Therefore, we surveyed pediatric urologists to determine their cur...

متن کامل

A systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia

  Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system.   Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...

متن کامل

Paediatric vesicoureteric reflux imaging: where are we? Novel ultrasound-based voiding urosonography.

Vesicoureteric reflux is an important association of paediatric urinary tract infection. Fluoroscopic micturating cystourethrography and radionuclide cystography have been employed for detecting and grading vesicoureteric reflux. However, both modalities involve ionising radiation, which can pose significant radiation risk to growing children. They also have a lower detection rate due to interm...

متن کامل

Health Monitoring for Composite under Low-Cycle Cyclic Loading, Considering Effects of Acoustic Emission Sensor Type

Composites have been widely used in the aerospace industry. Due to the requirement of a high safety for such structures, they could be considered for health monitoring. The acoustic emission approach is one of most effective methods for identifying damages in composites. In this article, standard specimens were made from carbon fibers and the epoxy resin, with the [03/902/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of radiology

دوره 57 1  شماره 

صفحات  -

تاریخ انتشار 2006