PURPOSE A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the user regarding the desired relative IGRT shifts. The DICOM header information defining the relative 4D dataset origin is then read in and the desired relative IGRT shifts are applied to re-define the origin for the dataset that is to be shifted. Lastly, the redefined (shifted) origin coordinates are written to the header of the 4D dataset and the dataset is then exported to AW as DICOM files. We used this program to process 4DCT datasets for four patients with 3-5 fractions each. The clinical shifts that were derived previously, without this program, were applied to the images and the acceptability of these shifts were evaluated. RESULTS All slices and planes of the shifted 4D dataset were reviewed and, in general, demonstrated acceptable re-centering of the target within the ITV. However, it is noted that some small adjustments to the shift coordinates would likely have been made had we had the opportunity to visualize the shifted 4D dataset as facilitated by the new in-house software. The additional adjustments for the four patient cases studied here had an average of lmm and maximum of 2mm in three principle directions. We look forward to exploring the potential for implementing this software into our clinical workflow, and we believe that such a workflow is worthy of consideration by vendors for implementation as an available feature in future versions of their software. CONCLUSIONS We presented a prototype program to shift 4DCT image set for lung SBRT applications and demonstrated four clinical cases.
منابع مشابه
Initial experience and clinical comparison of two image guidance methods for SBRT treatment: 4DCT versus respiratory‐triggered imaging
For Stereotactic Body Radiation Therapy (SBRT) treatment of lung and liver, we quantified the differences between two image guidance methods: 4DCT and ExacTrac respiratory-triggered imaging. Five different patients with five liver lesions and one lung lesion for a total of 19 SBRT delivered fractions were studied. For the 4DCT method, a manual registration process was used between the 4DCT imag...
متن کاملAccuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors
BACKGROUND To analyze the accuracy and inter-observer variability of image-guidance (IG) using 3D or 4D cone-beam CT (CBCT) technology in stereotactic body radiotherapy (SBRT) for lung tumors. MATERIALS AND METHODS Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours...
متن کاملThe colossal circumvention of the lung lesion during lung stereotaxy
This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...
متن کاملStereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters
Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...
متن کاملSU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.
PURPOSE Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering the target tracking during gantry rotation, we can significantly improve deliv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part16 شماره
صفحات -
تاریخ انتشار 2012