Pulmonary gas exchange and urinary electrolyte excretion during saturation-excursion diving to pressure equivalent to 800 and 1000 feet of seawater.

نویسندگان

  • K E Schaeffer
  • C R Carey
  • J Dougherty
چکیده

Two subjects carried out a saturation dive to 600 FSW with excursions to 800 feet of seawater (FSW). Two other subjects performed a saturation dive to 800 FSW. Both divers carried out two short excursion dives to 1050 and 1112 FSW followed later by an excursion dive to 1000 FSW lasting for 2-3/4 hours. All four divers noted helium tremors during their first excursion dive at depth exceeding 600 FSW and at very rapid compression rates ranging from 27-40 feet/min. The helium tremors were not observed during the second excursion dive at similar compression rates. In rest and exercise, PA^Q did not change significantly at depth, but showed considerable individual variations. Pulmonary gas exchange at rest remained within normal limits at depths of 800 and 1000 FSW. Exercise performed by two subjects at a moderate work load (100 watts) at 800 and 1000 FSW resulted in an increase of Cv> consumption, whereas CO« excretion tended to decrease. Tidal volume increased and respiratory rate decreased with increasing pressure in rest and exercise. A pronounced reduction in heart rate was observed under both conditions, which was attributed primarily to the effect of inert gas pressure, rather than to the effects of elevated PA . 2 Urinary COg excretion was significantly elevated during the saturation-excursion and decompression periods. The two subjects who complained about muscle pains in the leg, which did not respond immediately to recompression, showed peak urinary C02 excretion at the time the symptoms occurred. Hyperventilation and fluid shifts due to osmotic gradients of dissolved gases have been implicated as the most likely causes of the observed pattern of urinary electrolyte excretion during the saturation-excursion period and the decompression period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect on pulmonary functions of rapid compression in saturation-excursion dives to 1000 feet. USNSMC-573.

Four subjects were rapidly compressed at a rate of 2 — 3.5 feet per minute to 600 and 800-foot depths. They remained at saturation depths for 35 and 36 hours and carried out excursion dives lastingthree hours to 800 and 1,000 feet, respectively. Maximal Expiratory Flow Rate (MEFR) and Maximal Inspiratory Flow Rate (MIFR) measured with a Wedge spirometer at 200-foot increments during rapid compr...

متن کامل

Performance Effects of Increased Ambient Pressure : Ii

Two experienced, commercial divers were administered a simple addition test, a letter cancellation test, a geometric forms test and a choice reaction-time test (RATER) at selected intervals before, during and after a simulated, helium-oxygen dive in a pressure chamber complex to a saturated depth of 800 feet equivalent with excursion dives to 1000, 1050 and 1100 feet. The compression rate was 3...

متن کامل

INVOLVEMENT OF CO2 AND CALCIUM STORES IN DECOMPRESSION SICKNESS by

Analysis of urine electrolytes obtained during saturation excursion dives of four divers to depths equivalent to 800 and 1000 feet of sea water snowed in all cases during decompression an increase in urinary CO2 excretion and calcium excretionIn two subjects who developed symptoms of decompression sickness manifested in poorly localized muscle aches and stiffness of joints which did not respond...

متن کامل

Performance Effects of Increased Ambient Pressure

Two experienced commercial divers were administered an addition, a letter-cancellation and a form perception test before, at selected intervals, during, and after a simulated helium-oxygen dive to a saturation depth of 600 feet with excursions to 800 and 900 feet (total dive time 143 hours). Apart from vague joint and muscle sensations reported by means of a subjective checklist, the slow desce...

متن کامل

CO2 excretion and postcapillary pH equilibration in blood-perfused turtle lungs

Turtles possess a significant postcapillary CO2 partial pressure (PCO2) disequilibrium between arterial blood and alveolar gas. There are several possible explanations for this blood disequilibrium including a slow rate of erythrocyte physiological anion shift (Cl-/HCO3- exchange) or inaccessibility of plasma HCO3- to red blood cell or pulmonary carbonic anhydrase. The present study characteriz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aerospace medicine

دوره 41 8  شماره 

صفحات  -

تاریخ انتشار 1970