Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography

نویسندگان

  • Lele Cui
  • Ming Li
  • Meixiao Shen
  • Fan Lu
  • Jianhua Wang
چکیده

OBJECTIVES To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). METHODS A 1-day Acuvue® Define™ lens was tested on both eyes of 10 subjects (5 males and 5 females; mean age, 31.6 years). The centration and blink-induced movement of the contact lens were measured using UL-OCT at 5 min and 30 min after insertion. The measurements were repeated once at each checkpoint. RESULTS Good repeatability was found in the lens centration and movement between the two repeated measurements at either checkpoint. The values of the lens movement were 0.457 ± 0.248 mm and 0.402 ± 0.229 mm at 5 min and decreased to 0.197 ± 0.065 mm and 0.211 ± 0.110 mm at 30 min after insertion for the right and left eyes, respectively (P < 0.05). CONCLUSIONS The custom-built UL-OCT presented good repeatability of centration and movement in Define lenses at 5 min and 30 min after insertion. Most of the lenses were centered temporal and inferior to the cornea during the first 30 min wearing period. Compared with 5 min after insertion, the lens was centered better and exhibited less movement at 30 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

2mm Catheter Design for Endoscopic Optical Coherence Tomography

A biophotonics catheter was conceived with collimation optics, an axicon lens, and custom design imaging optics yielding a 360 degree scan aimed at imaging within concave structures such as arteries and lung lobes. The large depth of focus is necessary to image a long-depth-range sample with constant transverse resolution in optical coherence tomography (OCT). There are two approaches to achiev...

متن کامل

Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography

Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...

متن کامل

Development of cellular resolution Gabor-domain optical coherence microscopy for biomedical applications

We have developed a cellular resolution imaging modality, Gabor-Domain Optical Coherence Microscopy, which combines the high lateral resolution of confocal microscopy with the high sectioning capability of optical coherence tomography to image deep layers in tissues with high-contrast and volumetric resolution of 2 μm. A novelty of the custom microscope is the biomimetics that incorporates a li...

متن کامل

The influence of corneoscleral topography on soft contact lens fit.

PURPOSE To evaluate the influence of peripheral ocular topography, as evaluated by optical coherence tomography (OCT), compared with traditional measures of corneal profile using keratometry and videokeratoscopy, on soft contact lens fit. METHODS Ocular surface topography was analyzed in 50 subjects aged 22.8 years (SD ±5.0) using videokeratoscopy (central keratometry, corneal height, and sha...

متن کامل

Relationship between vessel diameter and depth measurements within the limbus using ultra-high resolution optical coherence tomography

PURPOSE To establish a relationship between the diameter and depth position of vessels in the superior and inferior corneo-scleral limbus using ultra-high resolution optical coherence tomography (UHR-OCT). METHODS Volumetric OCT images of the superior and inferior limbus were acquired from 14 healthy subjects with a research-grade UHR-OCT system. Differences in vessel diameter and depth betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017