Validation of improved recording site to measure phrenic conduction from surface electrodes in humans.
نویسندگان
چکیده
Phrenic nerve stimulation, electrical (ES) or from cervical magnetic stimulation (CMS), allows one to assess the diaphragm contractile properties and the conduction time of the phrenic nerve (PNCT) through recording of an electromyographic response, traditionally by using surface electrodes. Because of the coactivation of extradiaphragmatic muscles, signal contamination can jeopardize the determination of surface PNCTs. To address this, we compared PNCTs with ES and CMS from surface and needle diaphragm electrodes in five subjects (10 phrenic nerves). At a modified recording site, lower and more anterior than usual (lowest accessible intercostal space, costochondral junction) with electrodes 2 cm apart, surface and needle PNCTs were similar (CMS: 6.0 +/- 0.25 ms surface vs. 6.2 +/- 0.13 ms needle, not significant). Electrodes recording the activity of the most likely sources of signal contamination, i.e., the serratus anterior and pectoralis major, showed distinct responses from that of the diaphragm, their earlier occurrence strongly arguing against contamination. With ES and CMS, apparently uncontaminated signals could be consistently recorded from surface electrodes.
منابع مشابه
Diaphragm electromyogram measured with unilateral magnetic stimulation.
The purpose of this study was to establish the phrenic nerve conduction time (PNCT) for magnetic stimulation and further assess the relatively new technique of anterior unilateral magnetic stimulation (UMS) of the phrenic nerves in evaluating the diaphragm electromyogram (EMG). An oesophageal electrode was used to record the diaphragm compound muscle action potential (CMAP) elicited by supramax...
متن کاملSensory Nerve Conduction Near - Nerve Recording
Near-nerve recording of sensory action potentials evoked by electrical and tactile stimuli is a valuable tool in the assessment of nerve pathophysiology. In most instances where percutaneous recording fails to discriminate sensory potentials from noise they can be picked up by needle recording. To localize the site of focal injuries by determination of conduction across the presumed site of les...
متن کاملDiaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation.
The purpose of the study was to compare electrical stimulation (ES) and cervical magnetic stimulation (CMS) of the phrenic nerves for the measurement of the diaphragm compound muscle action potential (CMAP) and phrenic nerve conduction time. A specially designed esophageal catheter with three pairs of electrodes was used, with control of electrode positioning in 10 normal subjects. Pair A and p...
متن کاملDiaphragm electromyograms recorded from multiple surface electrodes following magnetic stimulation.
The diaphragm compound-muscle action potential (CMAPdi), elicited by unilateral magnetic stimulation (UMS) of the phrenic nerve can be recorded using surface electrodes. However, there is no consensus on the best positioning of surface electrodes and there are no data on the reproducibility of the signal. Using 36 surface electrode pairs, in five healthy subjects, the CMAPdi elicited by UMS and...
متن کاملPhrenic nerve stimulation in normal subjects and in patients with diaphragmatic weakness.
Phrenic nerve stimulation is often considered to be difficult and unreliable. The time taken for the phrenic nerves to be located and adequately stimulated was measured in 110 subjects, aged 21-89 years, 26 of whom had diaphragmatic weakness; and phrenic nerve conduction time was recorded in 76 of these individuals. Each phrenic nerve was stimulated transcutaneously in the neck with square wave...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 92 3 شماره
صفحات -
تاریخ انتشار 2002