Evaluation of MR/fluoroscopy-guided portosystemic shunt creation in a swine model.

نویسندگان

  • Aravind Arepally
  • Parag V Karmarkar
  • Di Qian
  • Brad Barnett
  • Ergin Atalar
چکیده

PURPOSE To evaluate three different percutaneous portosystemic shunts created with magnetic resonance (MR) imaging and fluoroscopy guidance in a swine model. MATERIALS AND METHODS In stage 1 of the experiment, an active MR intravascular needle system was created for needle tracking and extracaval punctures. Twenty inferior vena cava (IVC)/superior mesenteric vein (SMV)/portal vein (PV) punctures were performed in 10 swine (weight, 40-45 kg) in a 1.5-T short-bore interventional MR imager. With use of a real-time MR imaging sequence, the needle was guided through the IVC and into the SMV or PV (N = 20 punctures). After confirmation, a wire was advanced into the portal venous system under MR imaging guidance (N = 20). In stage 2, animals were transferred to the radiographic fluoroscopy suite for deployment of shunts. Three different shunts were evaluated in this study: (i) a commercial stent-graft, (ii) a prototype bridging stent, and (iii) a prototype nitinol vascular anastomotic device. Postprocedural necropsy was performed in all animals. RESULTS Successful MR-guided IVC/SMV punctures were performed in all 20 procedures (100%). All three shunts were deployed. Stent-grafts had the poorest mechanism for securing a shunt. The vascular anastomotic device and the bridging stent had more secure anchoring mechanisms but also had higher technical failure rates (50% and 40%, respectively). When deployed successfully, the vascular anastomotic device resulted in no bleeding at the sites of punctures at necropsy. CONCLUSION Percutaneous shunts and vascular anastomoses between the portal mesenteric venous system and IVC were successfully created with use of a combination of MR imaging and conventional fluoroscopy for guidance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of transabdominal ultrasound-guided transjugular portal vein puncture on radiation dose in transjugular intrahepatic portosystemic shunt formation.

PURPOSE Transjugular intrahepatic portosystemic shunt (TIPS) creation is used to treat portal hypertension complications. Often the most challenging and time-consuming step in the procedure is the portal vein (PV) puncture. TIPS procedures are associated with prolonged fluoroscopy time and high patient radiation exposures. We measured the impact of transabdominal ultrasound guidance for PV punc...

متن کامل

MR evaluation of portal hypertensive collateral shunting vessels for predicting outcome after transjugular intrahepatic portosystemic shunt.

PURPOSE We assessed whether magnetic resonance (MR) imaging evaluation of portosystemic collateral shunts can aid prediction of therapeutic effectiveness and complications after creation of a transjugular portosystemic shunt (TIPS), and technical difficulty during the TIPS procedure. MATERIALS AND METHODS We retrospectively reviewed 32 patients (27 men, 5 women; mean age, 56.4 years) who unde...

متن کامل

Transjugular intrahepatic portosystemic shunt creation using a three-dimensional fluoroscopy guidance system in patients with the Budd-Chiari syndrome.

When performed for Budd-Chiari syndrome (BCS), transjugular intrahepatic portosystemic shunt (TIPS) creation can be technically difficult due to hepatic congestion and asymmetric hypertrophy. We present three female patients with decompensated BCS in whom TIPS were created using a three-dimensional fluoroscopy guidance system. On a dedicated workstation using three-dimensional volumes of comput...

متن کامل

Efficacy of a Dexamethasone-Eluting Nitinol Stent on the Inhibition of Pseudointimal Hyperplasia in a Transjugular Intrahepatic Portosystemic Shunt: An Experimental Study in a Swine Model

OBJECTIVE We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudo-intimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. MATERIALS AND METHODS Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter....

متن کامل

Effects of Intraluminal Irradiation with Holmium-166 for TIPS Stenosis: Experimental Study in a Swine Model

OBJECTIVE We wanted to evaluate the effectiveness of intraluminal irradiation with Holmium-166 ((166)Ho) for reducing the pseudointimal hyperplasia (PIH) in the transjugular intrahepatic portosystemic shunt (TIPS) tract in a swine model. MATERIALS AND METHODS TIPS was performed in 12 domestic pigs, after the creation of portal hypertension by intraportal injection of a mixture of N-butyl-2-cy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 2006