Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma

نویسندگان

  • Chang Mok Lee
  • Young Cheol Yoo
چکیده

Purpose. To evaluate the short-term effect of standard automated perimetry (SAP) testing on intraocular pressure (IOP) in patients with open-angle glaucoma (OAG). Methods. We tested 45 patients (71 eyes) with OAG that had stable IOP under medical treatment. IOP was measured four times using an iCare rebound tonometer (RBT) immediately before, immediately after, 10 minutes after, and 20 minutes after SAP testing. Logistic regression analyses were performed to determine the relationships among SAP test duration, mean deviation of the SAP result, type of glaucoma medications, patient age, and significant IOP change (exceeding 2 mmHg) from baseline IOP. Results. The mean baseline IOP was 13.29 ± 3.06 mmHg. Although IOP changes immediately and 20 minutes after SAP testing were not statistically significant, the IOP change 10 minutes after SAP testing (-0.57 ± 1.84 mmHg) was statistically significant. However, the changes were within the margin of error of the RBT. Test duration, mean deviation, patient age, and type of glaucoma medications did not have a significant influence on IOP change (all P > 0.14). Conclusions. IOP measured by RBT did not vary significantly after SAP testing in patients with OAG. It may be not necessary to reject IOP measured after SAP testing in patients with OAG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma

PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinte...

متن کامل

Long-term fluctuation in short-wavelength automated perimetry in glaucoma suspects and glaucoma patients.

PURPOSE To determine the magnitude of the homogeneous, LF(Ho), and the heterogeneous, LF(He), components of the long-term fluctuation (LF) in glaucoma suspects and in stable primary open angle glaucoma (POAG) patients undergoing short-wavelength automated perimetry (SWAP) and to compare the magnitude of the SWAP LF components with those elicited by standard white-on-white (W-W) perimetry. MET...

متن کامل

Rescula as an alternative therapy for beta-blockers with long-term drift effect in glaucoma patients.

The purpose of this study was to evaluate both the intraocular pressure (IOP)-decreasing and neuroprotective effects of Rescula (0.12% unoprostone isopropyl) as an alternative therapy to betablockers with a long-term drift effect in patients with glaucoma. Twenty-eight patients with unilateral or bilateral glaucoma were treated with Rescula instead of the original beta-blocker therapy. IOP was ...

متن کامل

Motion automated perimetry identifies early glaucomatous field defects.

OBJECTIVE To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n...

متن کامل

Short-term effects of relaxation music on patients suffering from primary open-angle glaucoma

PURPOSE To evaluate whether additive relaxation music (RM) has an adjuvant short-term effect on physiological and psychological parameters in patients with primary open-angle glaucoma. METHODS Prospective, randomized clinical trial. Patients in the therapy group (TG) received a 30-minute RM via headphones, whereas members of the control group (CG) did not. Best corrected visual acuity, intrao...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013