Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium.
نویسندگان
چکیده
Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) medium. The mean time to detection of M. tuberculosis in smear-positive specimens was 12.6 days for BACTEC MGIT 960 medium, 13.8 days for BACTEC 12B medium, and 20.1 days for LJ medium, and in smear-negative specimens it was 15.8 days for BACTEC MGIT 960 medium, 17.7 days for BACTEC 12B medium, and 42.2 days for LJ medium. The rates of contamination were 3.7, 2.9, and 1.2% for the BACTEC MGIT 960, BACTEC 12B, and LJ media, respectively. In conclusion, the nonradiometric, fully automated 7-ml BACTEC MGIT 960 system can be considered a viable alternative to the semiautomated, radiometric BACTEC 460 TB system.
منابع مشابه
Evaluation of BACTEC Mycobacteria Growth Indicator Tube (MGIT 960) automated system for drug susceptibility testing of Mycobacterium tuberculosis.
The reliability of the BACTEC MGIT 960 system, an automated version of the Mycobacteria Growth Indicator Tube (MGIT), for antimicrobial susceptibility testing of Mycobacterium tuberculosis was evaluated on 78 clinical isolates. Rifampin (RMP), isoniazid (INH), streptomycin (SM), and ethambutol (EMB) were tested at the following concentrations: 1.0 microg/ml for RMP, 0.1 and 0.4 microg/ml for IN...
متن کاملComparison of BACTEC MGIT 960 system and BACTEC 460 TB system for growth and detection of Mycobacteria from clinical specimens.
This study was carried out to compare the performance of BACTEC MGIT 960 with the BACTEC 460 TB for growth and detection of Mycobacteria from human clinical specimens. The BACTEC MGIT 960 instrument is a fully automated system that utilizes MGIT tubes containing an oxygen sensor embedded in silicon at the bottom and filled with 7 mL of modified Middlebrook 7H9 broth. Identical samples were inoc...
متن کاملMulticenter evaluation of the BACTEC MGIT 960 system for recovery of mycobacteria.
We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC M...
متن کاملMulticenter evaluation of fully automated BACTEC Mycobacteria Growth Indicator Tube 960 system for susceptibility testing of Mycobacterium tuberculosis.
The reliability of the BACTEC Mycobacteria Growth Indicator Tube (MGIT) 960 system for testing of Mycobacterium tuberculosis susceptibility to the three front-line drugs (isoniazid [INH], rifampin [RIF], and ethambutol [EMB]) plus streptomycin (STR) was compared to that of the BACTEC 460 TB system. The proportion method was used to resolve discrepant results by an independent arbiter. One hundr...
متن کاملUse of BACTEC MGIT 960 for recovery of mycobacteria from clinical specimens: multicenter study.
The BACTEC MGIT 960 instrument is a fully automated system that exploits the fluorescence of an oxygen sensor to detect growth of mycobacteria in culture. Its performance was compared to those of the radiometric BACTEC 460 instrument and egg-based Lowenstein-Jensen medium. An identical volume of sample was inoculated in different media, and incubation was carried out for 6 weeks with the automa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 38 6 شماره
صفحات -
تاریخ انتشار 2000