Analysis of diaphragm movement during tidal breathing and during its activation while breath holding using MRI synchronized with spirometry.
نویسندگان
چکیده
Using magnetic resonance imaging (MRI) in conjunction with synchronized spirometry we analyzed and compared diaphragm movement during tidal breathing and voluntary movement of the diaphragm while breath holding. Breathing cycles of 16 healthy subjects were examined using a dynamic sequence (77 slices in sagittal plane during 20 s, 1NSA, 240x256, TR4.48, TE2.24, FA90, TSE1, FOV 328). The amplitude of movement of the apex and dorsal costophrenic angle of the diaphragm were measured for two test conditions: tidal breathing and voluntary breath holding. The maximal inferior and superior positions of the diaphragm were subtracted from the corresponding positions during voluntary movements while breath holding. The average amplitude of inferio-superior movement of the diaphragm apex during tidal breathing was 27.3+/-10.2 mm (mean +/- SD), and during voluntary movement while breath holding was 32.5+/-16.2 mm. Movement of the costophrenic angle was 39+/-17.6 mm during tidal breathing and 45.5+/-21.2 mm during voluntary movement while breath holding. The inferior position of the diaphragm was lower in 11 of 16 subjects (68.75 %) and identical in 2 of 16 (12.5 %) subjects during voluntary movement compared to the breath holding. Pearson's correlation coefficient was used to demonstrate that movement of the costophrenic angle and apex of the diaphragm had a linear relationship in both examined situations (r=0.876). A correlation was found between the amplitude of diaphragm movement during tidal breathing and lung volume (r=0.876). The amplitude of movement of the diaphragm with or without breathing showed no correlation to each other (r=0.074). The movement during tidal breathing shows a correlation with the changes in lung volumes. Dynamic MRI demonstrated that individuals are capable of moving their diaphragm voluntarily, but the amplitude of movement differs from person to person. In this study, the movements of the diaphragm apex and the costophrenic angle were synchronous during voluntary movement of the diaphragm while breath holding. Although the sample is small, this study confirms that the function of the diaphragm is not only respiratory but also postural and can be voluntarily controlled.
منابع مشابه
Infant cardiac MRI using oscillatory ventilation: safe and effective
Background Cardiac magnetic resonance imaging (CMRI) for infants and young children typically requires sedation. General anaesthesia can eliminate motion artefact and permits controlled ventilation with breath-holding during imaging to limit respiratory artefact, but this technique typically requires frequent changes in respiratory support that may impair pulmonary function, and pauses in image...
متن کاملLung MRI using an MR-compatible active breathing control (MR-ABC).
This work introduces an MR-compatible active breathing control device (MR-ABC) that can be applied to lung imaging. An MR-ABC consists of a pneumotachograph for respiratory monitoring and an airway-sealing unit. Using an MR-ABC, the subjects were forced to suspend breathing for short time intervals, which were used in turn for data acquisition. While the breathing flow was stopped, data acquisi...
متن کاملInitiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran
Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...
متن کاملInnovative exhaled breath analysis with old breathing manoeuvres-is there a problem or an advantage?
As the field of exhaled breath research is expanding, the question that arises is can the old usual method of spirometry be used in all cases? The answer is yes for some analysation methods and definitely not for others: it all depends on the result you are looking for. Exhaled breath condensate collection can be accomplished with silent tidal breathing, but not in the analysation of the amount...
متن کاملInvestigating the claims of Konstantin Buteyko, M.D., Ph.D.: the relationship of breath holding time to end tidal CO2 and other proposed measures of dysfunctional breathing.
OBJECTIVES Konstantin Buteyko, M.D., Ph.D., claimed that breath holding time (BHT) can be used to detect chronic hyperventilation and that BHT predicts alveolar CO(2) (Pa(CO(2))) according to his patented mathematical formula. The Buteyko Breathing Technique (BBT) is believed to correct chronic hyperventilation as evidenced by increased BHT. In this study, we test Buteyko's claims and explore t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological research
دوره 58 3 شماره
صفحات -
تاریخ انتشار 2009