Validation of a new hand-held electronic data capture method for continuous monitoring of subjective appetite sensations

نویسندگان

  • Catherine Gibbons
  • Phillipa Caudwell
  • Graham Finlayson
  • Neil King
  • John Blundell
چکیده

BACKGROUND When large scale trials are investigating the effects of interventions on appetite, it is paramount to efficiently monitor large amounts of human data. The original hand-held Electronic Appetite Ratings System (EARS) was designed to facilitate the administering and data management of visual analogue scales (VAS) of subjective appetite sensations. The purpose of this study was to validate a novel hand-held method (EARS II (HP® iPAQ)) against the standard Pen and Paper (P&P) method and the previously validated EARS. METHODS Twelve participants (5 male, 7 female, aged 18-40) were involved in a fully repeated measures design. Participants were randomly assigned in a crossover design, to either high fat (>48% fat) or low fat (<28% fat) meal days, one week apart and completed ratings using the three data capture methods ordered according to Latin Square. The first set of appetite sensations was completed in a fasted state, immediately before a fixed breakfast. Thereafter, appetite sensations were completed every thirty minutes for 4h. An ad libitum lunch was provided immediately before completing a final set of appetite sensations. RESULTS Repeated measures ANOVAs were conducted for ratings of hunger, fullness and desire to eat. There were no significant differences between P&P compared with either EARS or EARS II (p > 0.05). Correlation coefficients between P&P and EARS II, controlling for age and gender, were performed on Area Under the Curve ratings. R2 for Hunger (0.89), Fullness (0.96) and Desire to Eat (0.95) were statistically significant (p < 0.05). CONCLUSIONS EARS II was sensitive to the impact of a meal and recovery of appetite during the postprandial period and is therefore an effective device for monitoring appetite sensations. This study provides evidence and support for further validation of the novel EARS II method for monitoring appetite sensations during large scale studies. The added versatility means that future uses of the system provides the potential to monitor a range of other behavioural and physiological measures often important in clinical and free living trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new chart-independent method for fast identification of control level of industrial processes using continuous data

A new method is developed for a fast identification of the stability situation of industrial processes. The proposed method includes two factor ratios of the control constants for the upper and lower control limits to process these constants. An indication ratio is then defined as the ratio of the maximum data range value to the difference between the maximum and average values for individual d...

متن کامل

Handheld computers for data entry: high tech has its problems too

BACKGROUND The use of handheld computers in medicine has increased in the last decade, they are now used in a variety of clinical settings. There is an underlying assumption that electronic data capture is more accurate that paper-based data methods have been rarely tested. This report documents a study to compare the accuracy of hand held computer data capture versus more traditional paper-bas...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

The reproducibility of subjective appetite scores.

Although subjective appetite scores are widely used, studies on the reproducibility of this method are scarce. In the present study nine healthy, normal weight, young men recorded their subjective appetite sensations before and during 5 h after two different test meals A and B. The subjects tested each meal twice and in randomized order. Visual analogue scale (VAS) scores, 10 cm in length, were...

متن کامل

A new method for evaluation and comprehensive drought Monitoring in the Urmia Lake Basin using a Synthesized Drought Index (SDI)

Drought is a complex phenomenon caused by the breaking of water balance and it has always an impact on agricultural, ecological and socio-economic spheres. Although the drought indices deriving from remote sensing data have been used to monitor meteorological or agricultural drought, there are no indices that can suitably reflect the comprehensive information of drought from meteorological to a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2011