Atomic force microscopy: a novel approach to the detection of nanosized blood microparticles.
نویسندگان
چکیده
BACKGROUND Microparticles (MPs) are small vesicles released from cells of different origin, bearing surface antigens from parental cells. Elevated numbers of blood MPs have been reported in (cardio)vascular disorders and cancer. Most of these MPs are derived from platelets. OBJECTIVES To investigate whether atomic force microscopy (AFM) can be used to detect platelet-derived MPs and to define their size distribution. METHODS Blood MPs isolated from seven blood donors and three cancer patients were immobilized on a modified mica surface coated with an antibody against CD41 prior to AFM imaging. AFM was performed in liquid-tapping mode to detect CD41-positive MPs. In parallel, numbers of CD41-positive MPs were measured using flow cytometry. Mouse IgG1 isotype control was used as a negative control. RESULTS AFM topography measurements of the number of CD41-positive MPs were reproducible (coefficient of variation=16%). Assuming a spherical shape of unbound MPs, the calculated diameter of CD41-positive MPs (dsph) ranged from 10 to 475 nm (mean: 67.5+/-26.5 nm) and from 5 to 204 nm (mean: 51.4+/-14.9 nm) in blood donors and cancer patients, respectively. Numbers of CD41-positive MPs were 1000-fold higher than those measured by flow cytometry (3-702x10(9) L(-1) plasma vs. 11-626x10(6) L(-1) plasma). After filtration of isolated MPs through a 0.22-microm filter, CD41-positive MPs were still detectable in the filtrate by AFM (mean dsph: 37.2+/-11.6 nm), but not by flow cytometry. CONCLUSIONS AFM provides a novel method for the sensitive detection of defined subsets of MPs in the nanosize range, far below the lower limit of what can be measured by conventional flow cytometry.
منابع مشابه
Pre-analytical and analytical issues in the analysis of blood microparticles.
Results of plasma microparticles (MPs) measurements reported in the literature vary widely. This is clearly not only related to the lack of well-standardised MP assays, but also to variations in pre-analytical conditions. In this review we will discuss the pre-analytical variables related to plasma and MP preparation which may affect MP analysis. Additionally we will address several analytical ...
متن کاملDetermination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
Microparticles, also known as microvesicles, found in blood plasma, urine, and most other body fluids, may serve as valuable biomarkers of diseases such as cardiovascular diseases, systemic inflammatory disease, thrombosis, and cancer. Unfortunately, the detection and quantification of microparticles are hampered by the microscopic size of these particles and their relatively low abundance in b...
متن کاملHigh Resolution Image with Multi-wall Carbon Nanotube Atomic Force Microscopy Tip (RESEARCH NOTE)
In this paper, a simple and reproducible approach for attaching the multi-wall carbon nanotubes (MWNTs) to the apex of the atomic force microscope probe has been proposed. For this purpose, the dielectrophoresis method was applied due to its simple performance, cheapness and reliability. In this method, various parameters such as voltage, frequency, concentration of carbon nanotubes solution an...
متن کاملCoupling Analytical Methods for Detection of Microparticles: The Possibilities for Improvement
Microparticles (MPs) are considered important diagnostic biological markers in many diseases with promising predictive value. There are several methods that currently used for the detection of number and characterization of structure and features of MPs. Therefore, the MP detection methods have been remained pretty costly and time consuming. The review is depicted the perspectives to use coupli...
متن کاملImmobilization and detection of platelet-derived extracellular vesicles on functionalized silicon substrate: cytometric and spectrometric approach
Among the various biomarkers that are used to diagnose or monitor disease, extracellular vesicles (EVs) represent one of the most promising targets in the development of new therapeutic strategies and the application of new diagnostic methods. The detection of circulating platelet-derived microvesicles (PMVs) is a considerable challenge for laboratory diagnostics, especially in the preliminary ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of thrombosis and haemostasis : JTH
دوره 8 2 شماره
صفحات -
تاریخ انتشار 2010