Modeling and analysis of 100 KVA distribution transformer core saturation effect under non-sinusoidal supply
نویسندگان
چکیده
In transformers the main consequence of harmonic currents is an increase in losses, mainly in windings, because of the deformation of the leakage fields. Higher losses means that more heat is generated in the transformer so that the operating temperature increases, leading to deterioration of the insulation and a potential reduction in lifetime. This paper includes the effects of non-sinusoidal supply voltage on the 100kVA distribution transformer. This paper presents a hysteresis based transformer simulink model to estimate transformer saturation with nonsinusoidal supply. Magnetic core saturation of transformers and rotating machines generate harmonics. The phenomena of core saturation are described by the hysteresis curve. And also investigate the effect of supply voltage on the excitation current of a 100kVAdistribution transformer. This paper also observe the which harmonic is more dominating in a saturated transformer.
منابع مشابه
Modeling and analysis of 100 KVA distribution transformer including the core saturation effect
Magnetic core saturation of transformers and rotating machines generate harmonics. Harmonics are integer multiples of the fundamental frequency. Harmonics is caused by nonlinear devices in the power system. Due to the non-linear loads, power frequency harmonics exist mainly in distribution systems. The current harmonics cause voltage harmonics, hence resulting in nonsinusoidal supply voltage in...
متن کاملPrediction of Core Losses of Three-Phase Distribution Transformer
Transformers are normally designed and built for use at rated frequency and sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additional heating in transformer parts. It leads to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To prevent these p...
متن کاملComputation of Transformer Losses under the Effects of Non- Sinusoidal Currents
Transformers are normally designed and built for use at rated frequency and perfect sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additional heating in power system components. It leads to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To p...
متن کاملDesign and Simulation of a 100 kVA Intelligent Universal Transformer Enjoying the Voltage Ratio of 20kv:380v
In order to reduce the volume and size of distribution power transformer, precise and extended controlling of transformer output, the conventional transformers are replaced by intelligent universal transformers (IUTs). In this paper, an IUT, typical of Iran national grid, with the voltage ratio of 20kV:380 V is designed and simulated. Regarding the IUT implementation, a cascaded H-bridge invert...
متن کاملA New Model for Analysis of Unusual Mal-Operation of Differential Protection Due to the Ultra-Saturation Phenomenon during the Loaded Power Transformer Energization
In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...
متن کامل