The variability of applicator position among high dose rate intracavitary brachytherapy applications in cervical cancer patients treated with ring & tandem applicators.
نویسندگان
چکیده
OBJECTIVE To evaluate the interindividual and intraindividual applicator position variability in high dose rate ring and tandem intracavitary brachytherapy applications in locally advanced cervical cancer. PATIENTS AND METHODS Eight patients with locally advanced cervical cancer formed the study population. They had been treated in Dokuz Eylül University Department of Radiation Oncology between the years 2000 and 2005 with high dose rate intracavitary brachytherapy using ring and tandem applicators. The 3-dimensional geometric variation of the applicator center in craniocaudal, mediolateral and anteroposterior directions was determined on the basis of bony reference points in 24 pairs of orthogonal films obtained in the conventional simulator. Then the following evaluations were performed: 1) the applicator position variability in all applications (interindividual variability), 2) the intraindividual applicator position variability relative to the first application, 3) the intraindividual applicator position variability relative to the average of three applications. Among the potential factors that might influence the reproducibility of ring and tandem applications, age, stage, the period between external radiotherapy and brachytherapy were evaluated by univariate analysis. RESULTS Standard deviation of interindividual applicator variability was 3.83 mm in craniocaudal, 0.39 mm in mediolateral and 2.86 mm in anteroposterior directions. The standard deviation of intraindividual variability relative to the first application was 1.91 mm in craniocaudal, 0.4 mm in mediolateral, and 4.26 mm in anteroposterior directions. The standard deviation of intraindividual variability relative to the average of three applications was 0.95 mm in craniocaudal, 1.86 mm in mediolateral, and 1.24 mm in anteroposterior directions. According to univariate analysis, no factor influenced applicator position variability. CONCLUSIONS In order to extract definitive conclusions about factors that affect positional reproducibility of ring and tandem applicators, studies are needed that include larger numbers of patients.
منابع مشابه
Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary-Interstitial Techniques.
PURPOSE To perform a comprehensive comparative planning study evaluating the utility of the proposed direction modulated brachytherapy (DMBT) tandem applicator against standard applicators, in the setting of image guided adaptive brachytherapy of cervical cancer. METHODS AND MATERIALS A detailed conceptual article was published in 2014. The proposed DMBT tandem applicator has 6 peripheral gro...
متن کاملDosimetric evaluation of a combination of brachytherapy applicators for uterine cervix cancer with involvement of the distal vagina* Avaliação dosimétrica de uma combinação de aplicadores para braquiterapia de tumores do colo uterino com acometimento da porção distal da vagina
OBJECTIVE: To evaluate an alternative brachytherapy technique for uterine cervix cancer involving the distal vagina, without increasing the risk of toxicity. MATERIALS AND METHODS: Theoretical study comparing three different high-dose rate intracavitary brachytherapy applicators: intrauterine tandem and vaginal cylinder (TC); tandem/ring applicator combined with vaginal cylinder (TR+C); and a v...
متن کاملComparison of dose volume parameters evaluated using three forward planning – optimization techniques in cervical cancer brachytherapy involving two applicators
Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and ...
متن کاملInter-application displacement of brachytherapy dose received by the bladder and rectum of the patients with inoperable cervical cancer
BACKGROUND The aim of the study was to examine on the CT basis the inter-application displacement of the positions D0.1cc, D1cc and D2cc of the brachytherapy dose applied to the bladder and rectum of the patients with inoperable cervical cancer. PATIENTS AND METHODS This prospective study included 30 patients with cervical cancer who were treated by concomitant chemo-radiotherapy. HDR intraca...
متن کاملThe use of trans-applicator intracavitary ultrasonography in brachytherapy for cervical cancer: phantom study of a novel approach to 3D image-guided brachytherapy
PURPOSE To assess the feasibility of applying trans-applicator intracavitary ultrasonography to image-guided brachytherapy for cervical cancer. MATERIAL AND METHODS For this experiment, a phantom was created and included a polyethylene tube, intended to simulate a tandem applicator, which was inserted into chicken meat and embedded in agar, along with magnetic resonance imaging (MRI)-compatib...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Tumori
دوره 93 5 شماره
صفحات -
تاریخ انتشار 2007