Opaque perfect lenses

نویسندگان

  • Graeme W. Milton
  • Ross C. McPhedran
چکیده

The response of the “perfect lens”, consisting of a slab of lossless material of thickness d with εs = μs = −1 at one frequency ω0 is investigated. It is shown that as time progresses the lens becomes increasingly opaque to any physical TM line dipole source located a distance d0 < d/2 from the lens and which has been turned on at time t = 0. Here a physical source is defined as one which supplies a bounded amount of energy per unit time. In fact the lens cloaks the source so that it is not visible from behind the lens either. For sources which are turned on exponentially slowly there is an exact correspondence between the response of the perfect lens in the long time constant limit and the response of lossy lenses in the low loss limit. Contrary to the usual picture where the field intensity has a minimum at the front interface we find that the field diverges to infinity there in the long time constant limit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Opaque intraocular lens in intractable diplopia: case report].

Intractable diplopia has been described in many situations but poor results are the rule with standard treatment modalities. The authors report a case of a woman with long-standing strabismus and diplopia who failed to improve following surgery, prism, and occlusive spectacles or contact lenses. Then, she was submitted to phacoemulsification and opaque intraocular lens implantation, which succe...

متن کامل

On Perfect Lenses and Nihility

The canonical problem of a perfect lens with linear bianisotropic materials is formulated. Its solution is shown to be directly connected with the concept of nihility, the electromagnetic nilpotent. Perfect lenses as well as nihility remain unrealizable.

متن کامل

Age-related changes in local water and protein content of human eye lenses measured by Raman microspectroscopy.

The Raman microspectroscopic method was used to determine the local water and protein content in human lenses. In 18 lenses of varying age position-defined water/protein content measurements were carried out along the visual and the equatorial axis. A main characteristic of the human lens is its constant and relatively low protein content. In addition this constant nuclear value is reached with...

متن کامل

Opacification of lenses cultured in the presence of Pb

PURPOSE Occupational and environmental Pb-exposure is associated with protein aggregation diseases which typically present in elderly populations (Parkinsons and cataract). Post-translational processing of crystallins, the major structural proteins of the lens, is altered with short-term Pb-exposure in Fisher 344 rats. In addition, lenses from aged rats become opaque upon long-term exposure to ...

متن کامل

Protective effects of estrogen in a rat model of age-related cataracts.

Women have a higher incidence of cataracts, and epidemiologic data suggest that the increased risk may be caused by a lack of estrogen in postmenopausal years. We have examined the effects of estrogen on methylnitrosourea (MNU)-induced cataractogenesis in Sprague-Dawley rats. Animals were ovariectomized, injected with MNU, and treated with estradiol or estrone by a continuous-release, subcutane...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006